Ford 7.3L Power Stroke (1999-2003) :: Injector Hold Down Bolts Not Torque Down To Spec - Hard Starting?
I wanted to know what happens when the injector hold down bolts are not torqued down to spec, what problems would arise and could it be a reason for somewhat hard starting?
View 1 RepliesFord 7.3L Power Stroke (1999-2003) :: Re-torque During Glow Plug Replacement?
I will be changing all the glow plugs in a few days. Should I re-torque the head bolts or anything while I am in there? Don't want to button it back up and then wish I had done something while in there.
View 14 RepliesFord Super Duty (1999-2016) :: 2014 - Front Body Mount Bushing Replacement
The driver side front body mount bushing on my 2014 is gone which has the grill sitting on the bumper. I started to replace it, but the bolt is sized to the nut. ran off about 1/2 inch and that is it, it will not tighten or loosen anymore.
I cut the head off the bolt, but can not get the body high enough to remove the old bushing so i can cut the nut off flush with the rad support. Now I am trying to get the air filter box out so i can cut the top of the "nut cage" off to remove the bolt and nut out the top. but i can not figure out how it is held in.
I have the intake disconnected and the filter hat off, overflow tank hose disconnected, and two bolts holding the whole thing to the fender out, but it will still not budge. What am I missing here?
Ford 7.3L Power Stroke (1999-2003) :: Torque Specs For Tie Rods?
What are the torque specs for tie rods for a 4x4.
View 4 RepliesFord 7.3L Power Stroke (1999-2003) :: Torque Value For 13 Mm Belt Tensioner Nut?
Thought I had these bookmarked but not. What is the torque value for the 13 mm bolt , replacing the tensioner.
View 4 RepliesFord F-150 (2004-2008) :: 2006 5.4L - Oil Drain Plug Torque Spec?
Gonna change my oil in a hour or so and I was wondering what the torque spec is for the oil drain plug.
View 3 RepliesFord 7.3L Power Stroke (1999-2003) :: Blown Trans From Torque Converter?
So my transmission drove perfectly fine I just wanted to put an upgraded torque converter in especially after driving a customers' truck with a low stall converter. I know their not like for racing or anything but it's a work Truck with some mods to the motor nothing crazy. So I went ahead and bought a low stall triple disk converter and I drove around the block fine and went to go on the freeway and got into fourth but lost it as I hit 75 (was not flooring by any means and had it in the stock tune) now it will not go past second gear. Once it did this the o/d off light started to flash and I decided to do a stall test.went to 1800 in a Second. Suppose to stall around 1200-1300.
2000 f250 7.3 powerstroke dp chip stage 1 camshaft and 180/100 injectors coming at some point but stock for now
Ford 7.3L Power Stroke (1999-2003) :: Trans Torque Converter Rattle
1999 7.3/4r100 4wd with the rattling torque converter.
I bought this truck 10-11 years ago to use as a tow rig for my landscaping company. It has been a great problem free truck, I have done brakes a few times, a water pump, ball joints but no issues with motor/drivetrain.
I don't know the history of the trans before I purchased. Ford didn't have history of it being replaced and even now it still has all the labeling on the case. I would have thought it would have been washed off in a rebuild. Again I don't know. When I bought the truck it shifted nice and crisp, having owned trucks before it made me think it had been rebuilt but this was my first and only 4r100. Other trucks are ZF6 manuals.
Anyway 10 years and 100,000 miles later it still shifts very crisp and fluid, has been changed a couple times, is nice and cherry red. I added a 6.0 cooler, temp gauge and filter. Never see the temp rise and haven't seen much in the filter.
About 25,000 miles ago the TC started to rattle, a known 99 problem. I figured surely the trans would go and I would do a rebuilt from Ford. It keeps going though so being a work truck I have kept running it.
A couple weeks ago the starter just spun and wouldn't engage. I pulled the inspection cover and noticed some missing teeth on flex plate. Got it to start my turning crank bolt a bit to good teeth and the starter caught. Now we are carrying a breaker bar and socket. It has happened a few more times so I need to replace flex plate.
Question is, since I need to pull trans to replace flexplate, should I replace TC (I would like to get rid of the noise)? Some people have said I will be replacing trans in a couple months if I mess with it. They say just spend $3000 on a rebuilt now with a converter. Not trying to be cheap but hate to just dump this trans that is still working great and has served me well.
I have replaced many transmission and done clutches in many trucks so I am familiar with the steps of removal and installation, just stuck on what I should do.
Ford 7.3L Power Stroke (1999-2003) :: Torque Pro And SES Light When Pulling Fault Codes
I have a 2001 F350 with a PCM labeled "PMT2".
The SES light is triggered every time I try and pull fault codes using Torque Pro. It has done this since I installed Torque Pro many months ago. Same thing happens in another local member's (2000) truck, although I don't know his PCM version.
I'm very comfortable with the Torque Pro settings that have been detailed in other Torque Pro threads. I have been careful to choose conservative settings, including trying debug mode. I have uninstalled and reinstalled Torque Pro to see if that solves the problem - which it does not.
Question: "PMT2" PCM been able to pull fault codes using Torque Pro without tripping the SES light?
I realize another variable may be my OBD2 Bluetooth device. As an aside, I have removed the AIH and would expect to see a fault code but Torque Pro reports no fault codes.
Ford 7.3L Power Stroke (1999-2003) :: Service Engine Soon Light - No Codes In Torque
The SES light in my 2001 7.3 came on about a month ago while I was towing a light trailer in the SoCal mountains. When I got home I spent about 2 weeks replacing the injector o-rings and glow plugs. I discovered while I was in there that the head bolts on the driver's side where loose. I retorqued them to spec.
Both batteries were disconnected for the 2 weeks. When I started the truck the SES light was still on.
My Torque Pro app isn't showing any error codes, and is reading live data correctly. (I didn't have the app when the light first came on; I only purchased it after I finished the repairs). Am I missing something? Is the SES light not necessarily connected to fault codes? If so, wouldn't it reset after 2 weeks with the batteries disconnected?
Ford 7.3L Power Stroke (1999-2003) :: Torque Convertor Rattle After Transmission Rebuild
My '01 f350 up and running the last 5 years. The truck has 130,000 miles on it and the transmission quit on me two weeks ago. My mechanic pulled the tranny and sent it to a very reputable rebuilder for a complete rebuild. My mechanic then reinstalled the tranny. I picked up the truck and when I paid the bill my mechanic told me that the rebuilder provided a new 4-plate torque convertor and that I would hear it rattle when I was at stop signs, stop lights etc. and that this was normal for these types of torque convertors. I have searched this forum and found all kinds of reasons for this rattle. None of which tell me this noise is normal or should be expected. I have no problem going back to my mechanic and discussing flex plate cracks, engine/tranny misalignment or any of the other causes...
View 2 RepliesFord 7.3L Power Stroke (1999-2003) :: F250 - Transmission / Torque Convertor Slipping
My son bought a 1999 F250 Diesel about a year ago. The seller gave him receipts showing that the 4R100 had been rebuilt and a new T.C. installed 25k miles before the sale. The problem is that it is slipping. He says it started with 2nd gear, now it will hardly move in 1st.
Fluid smells a little burnt. We pulled the transmission pan expecting to find lots of friction material. It does not have as much as I thought it would, not as much as I have found in the the pans of the few other auto trans I have seen with worn out frictions. Below are pics of the inside of the pan.
Or, is it the T.C. that is slipping. I have never had a vehicle with a bad T.C. How do you diagnose it? I have experience rebuilding (GM) Turbo 400's and 4L60's. Never had a ford AT apart.
Ford 7.3L Power Stroke (1999-2003) :: Injector Installation - Torque Hold Down Bolts
I have been reading here about alternate methods to torquing the hold down bolts for the injectors. This winter I replaced my old stock split shots with new alliant single shots. I installed the injectors into a cold engine and torqued the hold down bolts to 10 ft lbs. I did not ever go back and re-tighten.
Is it suggested to go in and re-tighten the injector hold down bolts to 10 ft-lbs after the engine has been heated up and cooled down? What are some symptoms of a loose injector? I am imagining premature wear on the injector cups, low compression and maybe some mixing of oil into the combustion chamber.
Did just throw the injectors in and go back later to retorque only to find they were all fine or were some loose?
Ford 7.3L Power Stroke (1999-2003) :: Water Pump Lower Elbow Bolts Torque Specs
I read 18lbs for the water pump but it took a cheater bar (perhaps due to corrosion) to get the water pump lower elbow bolts off.
On reinstallation, what should the lower elbow bolts be torqued to? Checked the sticky (Ziggy's Torque Specs) but didn't see the specs for this item.
Corolla / Matrix 2009-13 :: ATF Drain Plug Size And Torque Spec
What is the ATF drain plug size and its torque spec?
View 3 RepliesFord 7.3L Power Stroke (1999-2003) :: Steering Box Replacement?
Looks like a pia but nothing too crazy.I don't have a pitman arm puller, but can borrow one.
View 14 RepliesFord Super Duty (1999-2016) :: 2001 F250 - Sway Bar Bushing Replacement?
I have a friend with an 01 f250 super duty who needs to replace sway bar bushings.
View 6 RepliesFord 7.3L Power Stroke (1999-2003) :: Hub And Wheel Bearing Replacement
I'm in the middle of replacing the hub and bearing assembly, once i got the hub assembly off, I noticed when I grab the axle there is a lot of play if I pull the axle up and down or left to right. Is this normal as the hub assembly holds it in position? I don't have any fluid leaking so the seal must be good, or am I missing something. I am trying to do this in 30 degree weather and it sucks.
View 10 RepliesFord 7.3L Power Stroke (1999-2003) :: Replacement Hubs - How Are They Holding Up
To those of you that have replaced your unit bearing hubs on your 4 x 4's; are they giving comparable service to the OEM units? I'm replacing ball-joints right now and it would sure be easy to slap on some new hubs. The only issue is I have 130k on the originals and have been lubing them through the ABS port for the last 20k miles - the hubs seem to be in good condition. I've noticed some posters stating that since lubing an already good hub, that they are now getting a lot more than the standard 150k out of them. I also worry about replacing perfectly good US bearing hubs with most likely a Chinese bearing hub (Timken or not!).
View 10 Replies