Ford Super Duty (1999-2016) :: After Auxiliary Tank Added Truck Runs Then Dies Out
I bought a 2003 F550 Super Duty 4WD, cab and chassis truck. It has a 7.3 TD. Real nice truck. I bought it to turn it into a wrecker. I removed the factory fuel tank (was behind the real axle inside the frame rails.) I installed a 50 gallon aluminum tank behind the cab on the frame rails. The rear tank has to be removed for the wheel lift.
Any way I have everything installed and now the truck dies out after a few minutes. It starts up fine then dies out like its starving for fuel. The tank I installed has a sump pickup (tank came off a freightliner, so its not some home made thing I just welded up in the garage)
I was thinking about installing an auxiliary lift pump as the auxiliary tank is a bit higher than the factory tank, but I want to solve the issue not throw parts at it. I thought at first injectors but it runs perfect after I prime it so my guess is its not the injectors.
Ford Super Duty (1999-2016) :: 2006 F250 - Coolant Leak Only When Truck Is Cold
I have a 2006 Ford F-250 coolant leak only when the truck is cold. Ive noticed it in the morning when I leaving for work. It looked liked it was coming from the passenger side yesterday and today it's on the drivers side when I'm sure is because my driveway has a small tilt to it I've looked everywhere I could under the hood and don't see it leaking.
I don't have any temp problems or white smoke and my coolant level has changed that much and for a few days the drip stopped now it's back. I tried to search for the answer but can't find it. I'm just wanted to make sure it's not the head gasket but I'm sure I would have a sign it it was. I will include where I saw it dripping from. It's parked on flat ground here ... That's where I saw a drip coming from driver side ....
Ford Super Duty (1999-2016) :: Heater Blowing Cold Then Truck Overheated And Pushing Coolant Out Of Cap
My '01 Super Duty 5.4 has an overheating/heater problem that the dealer can't seem to fix. I noticed my heater was blowing cold then a few miles later it overheated pushing coolant out of cap. Next day drove fine to Ford dealer who replaced my heater core, thermostat, reservoir cap and a hose. Drove it for a day till the exact original symptoms occurred again with a gurgling sound in dash. Dealer kept for a week pressurizing system but no leaks found. Replaced my thermostat again and gave it back. I drove it 300 miles over a week before the exact same symptoms occurred. Brought back to dealer who said that air was in the system, added a bunch of coolant and supposedly got all the air out. Same symptoms still. Brought back to dealer that finally changed the water pump they said had a leak. Guess what, same symptoms. Heater will work fine for days then it will blow cold, then hot, then cold and sooner or later truck will overheat then just as fast cool down and heater will work again. Still hearing gurgling. Dealer said I don't have a HCV.
View 6 RepliesFord A/C :: 1964 F100 - Coolant Overflow Tank Installation?
I got a 64 F100 with a 292 that I am thinking of installing a coolant overflow tank on to aliviate having to fill the radiator frequently.
The question being............Is it a sealed system or do I need to provide an air bleed to adjust for the presure change within the cylinder I intend to use?
I realise that thermal syphoning will return the coolant to the radiator but am unsure as to weather or not I need to allow the airspace to remain at atmospheric pressure.
Ford Super Duty (1999-2016) :: 2003 F250 - Oil Leaking From Back Of Passenger Head / Overflow Started Bubbling Over
I have a 03 250 gas 5.4 trying to find out the cooling system problem. I've found what I've read to be common oil leaking from back of passenger head. I had never noticed this before but it started very slight now overflow started bubbling over.
There is no coolant in oil no white smoke. My cooling system leak is just head gasket and gasket change could solve the problem or should I did deeper?
Ford Excursion :: Coolant Puking And Overflow Tank Smells Like Exhaust
I have owned my 2005 v10 ex since 60000 miles. Have had many dependable family road trips and love my truck.
Recently it has started puking coolant and the overflow tank smells like exhaust. The oil cap has some coolant sludge on it. But there is no coolant mixed with the oil. Or oil in the coolant.
I am pretty certain these are the signs of failing head gaskets. The truck has 193000 miles on it now.
Want to keep it on course. But keep it reliable. So do I buy new engine or do I just replace head gaskets?
Ford - Explorer :: Coolant Level Starts To Rise In Overflow Tank After Rev Up The Engine
I have a 2002 Ford Explorer and I am still trying to figure out why the coolant will overflow in the radiator reserve tank. I put in a new thermostat and a new cap to the overflow tank. When the tank is cold, sat over night, I put in new anti-freeze to the cold coolant line. Then I start up the explorer and let it run for a while. The temp gauge goes up, then drops a tad and cold air comes out of the vents.
After I rev up the engine, I see the coolant level starts to rise in the overflow tank, then it goes to the top and starts to leak out. This takes a while being the thermostat has not kicked in to suck the fluid in. Before this happens, the heater core lines are luke warm. After the tank overflows, the remaining gets sucked into the engine and I get nice warm heat. What causes this. I had the test done to see if the head gasket is bad. The test was negative.
Ford Ranger / B-Series :: 2000 - Muddy Coolant - Overflow Tank - Way To Clean?
Anyway here's the problem. My son has a 2000 Ranger 3.0L V6 he left me when he had to move back up to Las Vegas. I was out checking it out today and pulled the radiator cap, man what a mess. It looks like reddish mud in there and the overflow tank. It's not milky like oil in there it's more like mud. It's caked up on the bottom of the cap and inside the filler neck and the coolant looks the same.
So the questions are, what's the best way to clean it all out and what would cause it?
Ford Super Duty (1999-2016) :: V10 - How Many Gallons Is Gas Tank
Was thinking it was around 38 gallons but I'm thinking it's less than that. I have a 1999 Super Duty V10 with the long bed.
View 14 RepliesCelica :: 1993 5sfe - Coolant Overflow Tank Hoses On Cap?
Just finished a timing belt job on my 93 celica 5sfe. Filled the coolant up and burped engine. All seems to be well. My question is related to the coolant overflow tank. The cap has a hose attached on one end coming from the radiator and another coming out the other side that is short and L shaped. The L shaped hose isn't attached to anything and is open allowing air to either vent out or vent in to the overflow tank. There isn't any place nearby where the hose might attach to. Is this hose supposed to be "unattached" as it is now or should it be closed to create vacuum for the overflow tank to allow coolant back in to the radiator?
View 4 RepliesFord Super Duty (1999-2016) :: 2001 - Gas Tank Won't Fill Up?
I had a new Fuel Pump put in the cheaper plastic one into my 2001 F250 5.4 with a 112,000 miles.
Problem I am having since getting it back is when filling the gas tank up it will shut the pump off at 3/4 tank. I then have to sit there playing the squeezing game to get more gas in. The vent line looks fine no kinks in it and the tank looks level so what could be the issue causing me this headache?
Ford Super Duty (1999-2016) :: DEF Warning Came On / Cannot Fill Tank
Just got back from a 2500 mile trip and the 800 mile DEF warning came on. Went to a DEF pump but it just filled the neck. Went to another DEF pump, same . Went home and used a Ford DEF jug with the Ford spout. It still will not go in. If I squeeze the jug, I can hear a little bit dropping into the tank.
The vent and fill pipes are not kinked. The vent hole in the fill tube looks clear. I washed off the top of the tank since there is a vent there.
Still no fill. I do not have a bore scope to look in the fill tube. I ran a 1/2 inch flexible hose down the fill tube until it stopped. Still no fill.
Ford Super Duty (1999-2016) :: V10 Runs Rough With 1/2 Tank Of Gas
My truck started running poorly with an intermittent miss about 6000 miles ago. The miss gets more consistent when the tank is below 1/2. Fill it up and the miss goes away. No codes, shop that does a lot of V10 camper work could not figure it out.
My guess is that the fuel pump is going out and it overheats when the tank is low. The problem is getting progressively worse. Now it misses slightly with 3/4 tank and even a full tank sometimes.
Plugs have been changed, fuel filter has been changed, and the shop found 3 COPs that were bad before all this new intermittent miss started. The truck runs ok at wide open throttle.
Am I just nursing a bad fuel pump that will leave me standed soon? Truck has 170,000 mile with original fuel pump.
Ford Super Duty (1999-2016) :: 2001 - Dropping Gas Tank?
How hard is it to drop a gas tank from 2001 F250 short bed? It is a gasoline, not a diesel truck. I need to remove the filler neck to modify it and I cannot disconnect the hose from the neck filler to the tank while the tank is in the installed position. So, I want to drop it so I can have more leverage to pull it off or cut it off and put new one on.
View 7 RepliesCamry :: 2006 - Coolant Residue On Radiator / Overflow Tank Caps
While I was looking at my coolant level in the overflow tank yesterday I noticed pinkish coolant residue on the overflow tank cap and then looked at the radiator cap and it was covered in the same pinkish coolant residue.
2006 Cam LE 4 Cylinder, 52,000. Already done 2 coolant drain and fills--the Head bolt issue scares me.....
Ford Super Duty (1999-2016) :: 2015 - Fuel Tank Size?
It doesn't say on the window and in the owners manual I should have a 23 or a 35. The most I've put in my truck is 29.somthing and I had 3 miles till empty and the needle was in the red. I'm thinking I have a 30 gallon tank but how can I find out for sure.
I have a 2015 F250 6.2L CC SB FX4
Ford Super Duty (1999-2016) :: V10 - Run Sea Foam Through Booster Line And Gas Tank?
So my brother swears by sea Foam and has been telling me to run some of it through my truck. Question is,i just put new spark plugs in less then 5,000 miles ago. Will i have to change them if i run sea foam through the booster line and gas tank??
View 8 RepliesFord Super Duty (1999-2016) :: F250 - Fuel Tank Capacity?
I'm close to pulling the trigger on a Crew cab F-250 Powerstroke, 156" wheelbase. Need to know about fuel tank capacity? Ford's website and manual are somewhat cryptic. I believe it's 26 gallons.
View 3 RepliesDodge - Stratus :: 2005 - Overheats Constantly / Overflow Tank Keep Losing Coolant
So I have a 2005 Dodge Stratus. It must be a year old model because most of the parts and engine wise are of the 2006 model. Well earlier in Feb/March I had to get my timing belt and heads changed due to the bending. After that my car was working fine, but my coolant overflow tank kept losing coolant. Had that fixed with the repair shop as well. After that it seemed that my car was working well. Then it started to overheat, and I was informed that my lower radiator hose had a small leak. I had that fixed as well. This is when the constant overheating started.
I assumed that the air needed to be removed from the system. So I had it bleed, and then it seemed to work well, but that was not true seeing as my car continued to overheat of the cold air was on. The only thing that keeps it working is if I turn the heater on. That cools the system off. So now everyday I have to keep letting air out of the radiators, and run the heater if it gets too hot.
I just noticed today that my thermostat housing bolts have coolant on them whenever the engine gets to hot. Do you think it's not right enough, or my radiator cap may be bad?
Replacements:
Head gasket
Thermostat
Radiator hoses
I believe the cap of the radiator as well.