Accent MC (2006-11) :: Couldn't Engage Reverse When Put Shift Knob On
So I just installed my short shifter and everything works great, all the gears engage, however, when I put my shift knob on I noticed I couldn't engage reverse because it sits down too low and doesn't allow the reverse lockout to get over the rail and engage reverse. I have to loosen the knob so it sits higher and then I can engage reverse, but it moves around, so I can't leave it like this...right now my plan is to make some sort of spacer for the knob to sit on and then put loctite on it...seems like it would solve my problem. I have a Hyundai Aluminum shift knob and the short shift is OEM so I don't see what could be wrong ...
View 8 RepliesAccent MC (2006-11) :: Hatchback Trunk Door Knob Failure
I have a 08 Accent Hatchback. The trunk door knob(the black plastic hinge thing which you pull to open the trunk, not sure if I call it right) does not reset. I mean after pulling it to open the trunk, it's stuck instead of going back. I need to press it to original position, so the trunk door can be locked. I can see a rusty spring behind the black piece of plastic. Not sure where is the problem(maybe the spring?). How can I fix it.
View 20 RepliesAccent MC (2006-11) :: 2010 - AC Blower Not Turning On
AC Blower will not turn on. 10 and 40 amp fuse check good. Swap blower relay still blower will not turn on.
Is this problem common to the Accent 2010 model. Possibly the blower resistor open circuit.
Ford Escape / Hybrid :: 2006 - Fuse 26 Keeps Blowing / HVAC Blower Motor Turned Off
I have a 06 Mercury Mariner and this past week fuse #26 keeps blowing turning the HVAC blower motor off. I replaced the blower motor since i had one already in the garage and same thing is happening. The AC will run for awhile and in about 10/15 mins the fuse will blow. Fuse #26 is the Climate control system mode switch, are these known to go bad? Is this the part I should replace or look for other problems IE compressor?
View 2 RepliesAccent MC (2006-11) :: 2007 - A/C Vent Blower Has No Airflow Out
Recently, the air coming out of the vents has been intermittent, sometimes it blows sometimes it doesn't. I think I found the issue, the electrical contacts in the harness that plugs into the blower are either rusted out or have been almost burned out. Not as bad on the blower harness where this plugs in but I see some soot in there.
Once I removed this and tried wiggling it around, the blower comes on. Do I need to cut the harness and replace it with a new one or do I need to worry about the issue being traced somewhere else?
My girlfriend drives this car and she always has the A/C on either MAX or on the highest fan speed, I think that could be a culprit just from overuse. The other thing that comes to mind would be a wrong fuse or missing fuse somewhere, even though I checked the BLOWER fuse under the dash and under the hood and the relay. All of them are of the correct rating and do not look or smell burned out. (I'm not entirely positive on how to check/test relays)
Wiring Harness Socket that plugs into the blower : [URL] .....
Wiring Harness Socket on the blower : [URL] ....
Accent MC (2006-11) :: 2008 - Blower Motor Stopped Working
Got a 2008 Hyundai Accent. Yesterday, the blower motor just stopped working. I had just started it up, the heater came on for about five seconds. There was no noise, no funny smell, nobody had done anything to it. It just stopped. I checked the ac fuse and it looked fine. I looked in the fuse box under the hood, and I'd like to check the fusible link for the blower motor to see if it has a problem. Is this something I could do and how? Also is there anything else I can do to diagnose the cause of the problem?
View 2 RepliesFord F-150 (2004-2008) :: 2006 - Electrical Malfunction - Back Light Works Intermittently - Blower Fan Stop Blowing?
My 2006 F150 was purchased by me in early 2009 with about 28,000 miles on it. It's an XLT crew cab 4X4 with the 5.4. Stock except for a leveling kit and an aftermarket head unit. It currently has about 59,000 miles and has been babied since I purchased it. About 3 years ago I started noting some issues:
A. Oil pressure dummy gauge is all over the place. Some times it will show no oil pressure. Other times it is all the way to the highest mark. Other times the needle has gone 180 degrees past where normal is and is actualy pointing straight down towards the floor.
B. Recently my alternator dummy gauge has started doing the same thing as my oil pressure gauge.
C. The backlight behind my odometer works intermittently, but mostly not at all.
D. My dome light will flicker when first turned on. It doesn't matter which door is opened or if the override switch it turned on. It takes several seconds to come on and will flicker like there is a poor connection somewhere, but stays on once its on.
E. Blower fan will occasionally stop blowing. Once the climate control switch is turned to off, then back to on it resumes working. This doesn't happen often, but does occasionally.
Fortunately, the truck has not left me stranded and I want to keep it that way. We are getting ready to sale my wife's Toyota and this will become her daily driver. I want to take care of any issues before she starts driving it. Are these all separate issues or is there one common issue which could be causing them all?
Accent RB (2012+) :: Removing Automatic Shift Knob?
How is this done?
View 5 RepliesAccent LC (2000-05) :: 2001 - Heater Blows Air To One Face Only No Matter What Position The Knob Is In
My 2001 Accent heater only blows air to your face no matter what position the knob is in.
View 3 RepliesPrius (2004-09) :: Blowing Hot Air From Blower When Off
My 2009 prius blows hot air from the fan even when the fan/heater is off. This usually happens when I am driving >40mph on the freeway and as soon as I speed up to merge or overtake, the fan turns on and blows hot air?
View 5 RepliesGolf V R32 :: No Heat Or AC - Blower Stopped Blowing Any Air
My R stopped blowing any air. I can just barely feel warmth coming from the vents, but blower is not working... I looked for some threads on this but nothing.
View 2 RepliesFord A/C :: 2003 - Blower Stopped Blowing Any Air?
I took my truck to autozone to get a new flasher relay because my old one was making alll sorts of noise. After replacing nothing was fixed. I moved my tilt steering up and magically my blinkers worked. In the mean time the autozone guy was messing with the relays under the steering column and then in noticed my heater wasn't blowing any air, i turned it to A/C and still nothing, defrost nothing. so I replaced the relay next to the flasher relay and still nothing? Also the manual says nothing about a fuse designated to the blower fan, and all fuses checked out ok!!
View 4 RepliesSanta Fe (CM - 2007-12) :: AC / Heater - Blower Stopped Blowing Air
My 2009 Santa Fe GLS a/c, heater, etc. blower has stopped blowing air. I have checked the fuses, did the push test on the air adjustment button but nothing has worked. Sometimes it's like I can feel a VERY SMALL amount of air blowing out the vents.
View 3 RepliesFord A/C :: Water Blowing On Floor When Blower Is On After A Lot Of Rain
Seems like when we get alot of rain and i run the blower in the truck water will blow out on the passenger side floor. it only happens for a minute or to and u can hear it swishing around in there. I blew the condensate hose that sticks out about the passenger side wheel well that drains the AC condensate is there something else i should be looking for? a mixing door that isn't closing? Some sort of drain in the blower clogged? its not antifreeze leaking. it is water.
View 2 RepliesFord - Explorer :: 2004 - A/C Blower Keeps Blowing Fuses
Why the rear Auxiliary A/C blower on a 2004 Sport Trac keeps blowing fuses and how to fix it?
View 12 RepliesChevrolet - Blazer :: Blower Fan Started Intermittently Blowing And Eventually Quit
Around 8 months ago my blower fan started intermittently blowing and eventually quit. The chain shop near my house told me no question it was the blower motor gone bad. Last night I replaced the blower motor (pretty cheap part) and still nothing. I can feel the engine change idle when I turn the cooler on but nothing blows. My regular mechanic told me he thought it was the resistor based on my description (though I had assumed with a resistor issue it would tend to blow on low speed but not high and this blows never). What it could be?
View 4 RepliesVolvo :: 1989 740GL Blower Motor Doesn't Work / Keeps Blowing Fuses
My 1989 740GL has a blower motor that doesn't work; I looked into it and discovered a blown 30A fuse. So I replaced fuse and guess what? "POP"! No luck... It keeps blowing them, so I really haven't looked that far into it, but where I might start?
View 2 RepliesChevrolet - Blazer :: 1995 Blower Fan Started Intermittently Blowing And Eventually Quit
Around 8 months ago my blower fan started intermittently blowing and eventually quit. The chain shop near my house told me no question it was the blower motor gone bad. Last night I replaced the blower motor (pretty cheap part) and still nothing. I can feel the engine change idle when I turn the cooler on but nothing blows. My regular mechanic told me he thought it was the resistor based on my description (though I had assumed with a resistor issue it would tend to blow on high speed but not low and this blows never).
The diagnostic fee if it isn't the resistor is $60 an hour so I have a feeling it will be cheaper to just swap out all the parts. I have a feeling it is the relay but I am worried that since I can tell the engine changes idle when I turn the AC on it isn't, though I do not know for sure. Also if it is the relay there are three relays against the firewall and I am not sure which it is as the cases on them all appear to the untrained eye to be identical. Included is a picture. Which relay is the blower relay.
Chevrolet - Silverado :: 1995 / C1500 - Air Conditioning Blower Stops Blowing Air While Driving
I have a 1995 Chevy C1500 Silverado. The blower and heater work great when I start driving. After about 20 minutes of driving on high blower speed, the strength of air blowing out reduces drastically and eventually no air is blowing out of the vents. I can still hear that the blower is blowing air, but there is no air coming out of the vent. The Midas repair shop I frequent couldn't reproduce the issue on their short test drive (of course). They told me to bring it back to them whenever the problem occurs. I haven't had the opportunity because by the time I get out of work, they are closed and I am freezing to death every morning.
View 1 Replies