Ford - Mountaineer :: 2008 - Blower Motor Runs On Full Blast / Does Not Change Speeds

I have a 2008 mountaineer that the blower motor runs on full blast no matter what. The switch bars go up and down but blower motor does not change speeds. also upon opening the hood I found 2 large mouse nests ,1 on passenger side fender and 1 center of engine towards the back. Are these related or could it be a switch issue. How to remove switch and test it.

View 11 Replies

Sonata NF (2006-10) :: AC / Heater Blower Only Work On Full Blast

I have a 2006 Sonata and just a few weeks ago the AC/Heater Blower would only work on full blast. You actually had to have the control set a little before the full setting to get it to come on. Both the heat and the AC worked. Now, nothing is coming out on any speed setting. I've replaced the blower resistor and checked the fuses/relay and they seem fine.

View 2 Replies

Santa Fe (CM - 2007-12) :: A/C Blower Started To Change Speed Then Stayed At Full Blast

I was driving today and at a traffic light a severe smell of burnt plastic filled the cabin and the A/C blower started to change speed than stayed at full blast and even if I'd turn the knob from side to side or tried to shut everything off with the ""OFF""button nothing would happen........so we drove home and at some point it shut itself off...tried it again and seems ok now.....every dealer closed today and leaving for the USA tomorrow morning.... What the problem could be?

View 5 Replies

Ford Super Duty (1999-2016) :: 2003 - Blower Motor Loud Rumble Noise?

I have a 2003 super duty V10 4WD super cab long bed.

loud deep rumble noise when turn on the blower. both heat and a/c. removed the blower and seemed to turn ok. blew out all vents. removed heater radiator cover, checked most flaps to see if working. doesn't seem to be obstruction invent. the flap behind blower clear and functioning ok.

When on second speed, almost sounds like blower motor is out of balance. if run on high for 1 minute, smell electrical burning! Think to replace motor will work? will post another issue with radio and power windows

View 8 Replies

Prius (2004-09) :: Blower Motor Stopped Coming On All The Time

2004 Prius, 135,000 miles.

About a month ago, the blower motor stopped coming on all the time. A quick whack under the glove box fixed it when it didn't start. Then about a week after that, I felt like the AC wasn't really warming when needed. This may have been true earlier, but it hasn't been that cold around here, so I wouldn't have noticed, perhaps.

About a week ago, I start hearing what I might describe as a rattling kind of noise I had never heard before sometimes under hard acceleration. Not always. Didn't hear the noise tonight, for example. Of course, then, tonight, on the interstate, the warning light pops up for just long enough for the temperature indicator to flash up. It quickly disappeared, but in the remaining two minutes I was driving, it flashed up briefly twice more.

Now, in digging around on this topic, I've read about issues with the inverter coolant pump, and that there was a recall. How could I find some information on this recall? I don't remember ever having it changed, so I'm just curious what I might need to say to get that swapped out under a recall if appropriate.

Also, based on what I've said, does it seem likely that the issue is with that pump? It sure seems to fit the bill, but who knows. I'll be bringing the car in ASAP but I'd naturally like to be armed with as much information as possible.

View 2 Replies

Phaeton :: Radiator Fans Coming On At Full Blast On Cold Morning

Lately, I've noticed that when I start the car in the morning, the radiator fans come on at full blast, even though it's around 20 degrees F (not all the time, but most days). My temperature gauges all show (what I assume are) correct temps as it starts out cold, water first goes to 200 and stops, then oil slowly climbs and stops at 200 I believe.

They don't climb any faster or slower that I've seen, and usually by the time I get to work (around 20 minutes), the oil temp has probably climbed about 3/4 of the way to normal while the water is steady at 200.

Is this normal? I don't recall this happening, as I would've noticed as the fans are quite loud at full blast. I haven't had a chance to run a diagnostic scan yet, but the car hasn't warned me of anything either.

View 6 Replies

Prius (Gen 2) :: 2006 - Battery Died, One Purple Bar And Fan Was On Full Blast

My Prius' battery died this week after a respectable 163731 miles. I barely got it to the dealership . It was sluggish, engine racing, one purple bar and the battery fan was going full blast. It totally freaked me out.

21 working days for battery from Japan. I've been expecting it. I figure I can then drive the car for another couple of years.

View 1 Replies

Ford F-150 (2004-2008) :: Heater / Air Conditioning Fan Only Works On Full Blast (level 4)

Recently my truck is only blowing heat or air conditioning on full blast in my 2004 Ford F-150 (New style, not heritage).

Level 1, 2, or 3 is exactly the same and blows almost nothing, then if I switch it to 4 it is full power.

I just don't know what exactly I will need to change. I know it would be a resistor pack somewhere that probably failed, I just don't know where it would be.

Do I just need a new control switch, or do I need a new heater fan?

View 5 Replies

Honda - Accord :: 2002 - AC Making Loud Roaring Noise When Turned On Full Blast

I have a 2002 Honda Accord coupe with 130K miles on it. A few days ago the AC started to make a loud roaring noise when it is turned on full blast. As you turn it down the noise gets quieter and when the fan is on low the roaring noise stops. Other than making this sound it is running fine and there are no other issues/noises coming from the car. What is causing this noise?

View 3 Replies

Prius (Gen 3) :: Blower Motor Making Noise

My prius that I got about 1 1/2 years ago (2013 model) was making some noise. After conducting a few experiments I came to the conclusion it was the heat that was causing it. I removed the glovebox and lower plastic panel as well to see if it was actually the blower that was making the noise. And it was the blower.

So now it's like 20 degrees outside and I haven't used the heat because I didn't want to blow something so gotta get this fixed ASAP.

Like I mentioned glovebox and lower panel are open I've removed 2 of the 3 screws necessary to remove the blower. So the problem lies with the 3rd screw. There is a plastic socket with wires that is preventing me from reaching the 3rd screw so I have to remove that socket. So I have a couple pictures and how I can remove this so I can access the blower motor.

Also isn't it strange that the car isn't even 3 years old and the blower is giving me problems?

View 13 Replies

Prius (2004-09) :: Electrical System Not Getting To Blower Motor

Recently my a/c in my 2007 prius has been on the fritz. Some days it chooses not to blow any air at all. Others it will blow upon start up with cool air. I just took a road trip and it didn't work for 2 hours then magically came on blowing cold air. I took it in to the local shop to see if they could figure out the issue. To my disappointment, all the "parts" appear to be in good working order. The technician said that the electrical system just wasn't getting to the blower motor and that I should take it in to Toyota.

View 4 Replies

Prius (2004-09) :: 2006 - HVAC Blower Motor Replacement?

I am struggling with it, and need to get it done - by myself, as I can't afford a service job. I am handy, and comfortable doing it, But I am confused about how to get into the blower housing.

View 4 Replies

Prius (2004-09) :: 2008 - Blower Motor Intermittent / Only Works When Spin It

blower motor was intermittent on my 08 prius, now only works when i spin it. Looking for a pdf or instructions on replacing it myself?

View 1 Replies

Prius (2004-09) :: Blower Fan Intermittent / Motor Dying A Slow Death

I have started to have very intermittent problem with the blower fan. When I turn the fan on or auto, no fan blows.

If I hit the dash, over top of the display screen it will engage and start blowing.

2007 with 115k miles. I assume this is the blower motor dying a slow death.

I also assume this is not a DIY and will be expensive to fix.

View 7 Replies

Passat (B5) :: Heater And AC On / No Air Came Out Of Vents At All Even On Full Blast

My heater and a/c on my car have been acting up!

Yesterday I got into my car I turned on my heater and it didn't work! So I pushed the a/c button and that did nothing either! No air came out of the vents at all even on full blast... So I tried turning it off and back on and nothing happen then it finally worked but when i tried to turn it off it wouldn't turn off then randomly turned off by its self!!!

Whats going on and what I should check for this problem ?

View 6 Replies

Lincoln - Towncar :: Fan For Heat Or AC Will Only Run At Full Blast Or Nothing

My dad's 1993 Lincoln Town Car runs great but the fan for heat or AC only will run at full blast or nothing. Makes it difficult to drive when it's real hot or cold out. Can this be remedied without costing an arm and a leg? The car is 21 yrs. old and not worth a lot.

View 8 Replies

Prius (2004-09) :: Excessive Wind Noise On Highway And Mild Clunk When Engine Kicks On

I'm loving this 'new' 2004 prius with 177k miles on it that i just bought. In New England winters I'm still getting 40-45 mpg and I'm not even trying to get great MPG's.

1.) Wind noise : My biggest disappointment is excessive wind noise over 55 mph. I 'm using this car as a taxi and its so loud inside I'm a little embarrassed with customers in the car. It sounds to me that its coming from the passenger window or passenger side near the windshield, but I can not identify its location at all. I've always been the one driving when looking for it though.

I called a dealer that sells lots of gen II used prius's and he says its fairly common to replace the window seals? The car has a clean car fax.

2.) Mild clunk when the engine kicks on. Not all the time, but sometimes : Other thing is, I can sometimes feel and hear a mild clunk when the engine kicks on. I also feel a little bit if vibration when the engine is on and i'm idling (it was 16 degrees last night so the engine stays on for heat). The oil level is good. I'm due for change in the next 500 miles.

Is this anything I should be concerned about? I'm sure I'm just overly sensitive.

View 6 Replies

Caravan/Voyager :: 1998 - Heater Fan In Van Only Work On Full Blast

The heater fan in the van will only work on full blast and the rear wiper/ ac button lights flash which I had another 98 caravan that I was driving that had the same issue with the flashing lights. What is that all about?

View 2 Replies

Subaru - Forester :: 2005 2.5 Non Turbo Overheating - Cooling Fan Is Always Going At Full Blast

I have a 2005 Subaru Forester with 88k on it. I bought it with about 70k on and have been doing a lot of the services myself.

I change the oil religiously. I recently changed the thermostat on the car, cleaned out the reservoir and now the car has new antifreeze. The reason I did this was because cars cooling fan is always going at full blast. This only started about 6,000 miles ago. So since it was a easy job I figured change the thermostat. I am in NY and it has been very cold out, but with my 10 mile commute to work by the time I pull into the parking lot the cooling fan is very loud and the noise is very noticeable.

I recently drove up to go skiing, ( the temp outside was 9 degrees) I was on the interstate going about 70 to 77 mph because the car was going uphill and the incline was significant , I would push more on the gas pedal and I would see the thermostat on the dash going up very closely to the red mark. I pulled over a few time, the fans were at full blast.

View 6 Replies