Prius (2004-09) :: 2008 - Blower Motor Intermittent / Only Works When Spin It
blower motor was intermittent on my 08 prius, now only works when i spin it. Looking for a pdf or instructions on replacing it myself?
View 1 RepliesPrius (2004-09) :: 2006 - Intermittent Red Triangle Of Death
Our '06 has 68K on it. Last weekend I changed the front bumper (just cracked from small accident last year) and changed the oil. Used Mobil 1 5/30 and a Fram Oil Filter.
After about 125 miles of driving intermittent Red T.O.D. Always when ICE is running.
Oil level is OK - not loosing any oil. Filter and bolt on the pan are fine - no leaks.
Prius (2004-09) :: Intermittent Red Triangle Of Death After Making A Sharp Left Turn
I have a 2006 with 106K miles. Noticed after making a sharp left turn in a parking lot that the Red Triangle came on along with a beep and the message, "Problem" on the touch screen. Started happening more frequently either when the wheel is turning left or if I'm driving straight and the car drifts a little towards the left if I'm on the highway. Today it happened about 6 times. Warning goes off after a couple of seconds.
View 9 RepliesPrius (2004-09) :: Electrical System Not Getting To Blower Motor
Recently my a/c in my 2007 prius has been on the fritz. Some days it chooses not to blow any air at all. Others it will blow upon start up with cool air. I just took a road trip and it didn't work for 2 hours then magically came on blowing cold air. I took it in to the local shop to see if they could figure out the issue. To my disappointment, all the "parts" appear to be in good working order. The technician said that the electrical system just wasn't getting to the blower motor and that I should take it in to Toyota.
View 4 RepliesPrius (2004-09) :: Blower Motor Stopped Coming On All The Time
2004 Prius, 135,000 miles.
About a month ago, the blower motor stopped coming on all the time. A quick whack under the glove box fixed it when it didn't start. Then about a week after that, I felt like the AC wasn't really warming when needed. This may have been true earlier, but it hasn't been that cold around here, so I wouldn't have noticed, perhaps.
About a week ago, I start hearing what I might describe as a rattling kind of noise I had never heard before sometimes under hard acceleration. Not always. Didn't hear the noise tonight, for example. Of course, then, tonight, on the interstate, the warning light pops up for just long enough for the temperature indicator to flash up. It quickly disappeared, but in the remaining two minutes I was driving, it flashed up briefly twice more.
Now, in digging around on this topic, I've read about issues with the inverter coolant pump, and that there was a recall. How could I find some information on this recall? I don't remember ever having it changed, so I'm just curious what I might need to say to get that swapped out under a recall if appropriate.
Also, based on what I've said, does it seem likely that the issue is with that pump? It sure seems to fit the bill, but who knows. I'll be bringing the car in ASAP but I'd naturally like to be armed with as much information as possible.
Prius (2004-09) :: 2006 - HVAC Blower Motor Replacement?
I am struggling with it, and need to get it done - by myself, as I can't afford a service job. I am handy, and comfortable doing it, But I am confused about how to get into the blower housing.
View 4 RepliesPrius (2004-09) :: Rumble Noise Coming From Blower Motor When AC Kicks In Full Blast
I noticed that I have an unusual "rumble" noise coming from the location of my ac blower motor when it kicks in full blast. When the air temp comes down a bit and the AC slows down or if I switch the ac off full blast under climate control, the noise goes away. I have never noticed this before and am wondering if it is my ac blower motor starting to fail.
View 3 RepliesFord - Explorer :: 2004 - Randomly Dying At Slow Speeds - Code P0456
My wife drives a 2004 2WD Explorer with the 4.0 SOHC motor. We have had a problem now for over a year and a half of it randomly dying. There is not telling when the engine might die besides the fact that it happens when you let off the accelerator to brake or make a turn. It only happens at slow speeds. At a stop light or stop sign usually. The car will always start right back up. It has been to a couple of Ford dealerships and they haven't been able to diagnose the problem. The check engine light is on and it is giving the code p0456. This code definition is an EVAP small leak detected. Probable causes for the code are:
1. Defective, loose, or missing fuel cap.
2. EVAP Canister broke, hose cracked or not connected.
3. Purge or vent solenoid defective.
4. Vacuum leak at engine.
I don't think it's the fuel cap that would be making the car die. I used carburetor cleaner (I know its not the safest ) and sprayed on the vacuum lines that I could find to try and diagnose a vacuum line leak but nothing seemed to effect the engine. Do one of the other probable causes from p0456 could be causing the dying or could it be something else???
Ford F-150 (2004-2008) :: Intermittent Rattle / Knock / Running Rough And Dying At Stops
I am working on a customers 08 F-350 5.4l has 135k on it. came in with a severe rattle/knock, running poorly, and dying at stops. ECM gave up 8 codes relating to the timing... Found the phaser replacement steps here on FTE and followed them and replaced the VCT solenoids since i was in there. Customer reported that he replaced the cam sensors already. Ran great for a day, and the next day when I pulled into the shop it gave me a rattle. Not as violent as before but noticeable. I special ordered the wedge and followed the replacement to a 'T'. I have no performance issues and no codes.
View 5 RepliesPrius (Gen 3) :: Blower Motor Making Noise
My prius that I got about 1 1/2 years ago (2013 model) was making some noise. After conducting a few experiments I came to the conclusion it was the heat that was causing it. I removed the glovebox and lower plastic panel as well to see if it was actually the blower that was making the noise. And it was the blower.
So now it's like 20 degrees outside and I haven't used the heat because I didn't want to blow something so gotta get this fixed ASAP.
Like I mentioned glovebox and lower panel are open I've removed 2 of the 3 screws necessary to remove the blower. So the problem lies with the 3rd screw. There is a plastic socket with wires that is preventing me from reaching the 3rd screw so I have to remove that socket. So I have a couple pictures and how I can remove this so I can access the blower motor.
Also isn't it strange that the car isn't even 3 years old and the blower is giving me problems?
Prius (Gen 1) :: Blower Motor Replacement / Way To Get It Under Glove Box?
How to replace blower motor in 01 Prius. There are no way to get from to it from under the glove box.
Blower motor was working fine. I decided to remove cabin filter. Filter had not been changed for very long time. There was a lot of dirt, pine straw and leaves on top of the filter. When I removed the filter a lot of dirt fell inside the motor. Ever since then motor is working on and off. Often have to hit under the glove box and it works again for a while. Tried to remove the blower but could not get to it.
Prius (Gen 3) :: Blower Motor Not Working After Replacement
Several weeks ago, the blower motor in my 2010 stopped blowing. It came on within a day or so, but failed again, so I replaced it with a new part from Rock Auto: TYC 700249.
The new fan just stopped again. I plugged the harness in and out several times and it did briefly come on a few times, but clearly something else is going on.
I don't know if it's relevant, but after I took out the OEM fan, I experimented by removing the plate from its back that has wires and capacitors (actually, I don't know what I'm talking about) and connected the main prongs directly to a 12V battery. It came on right away. I installed the new fan anyway, figuring it was the plate/wires assembly portion that was bad. The "resistor?"
Prius (Gen 2) :: 2008 - Intermittent Blower In Cabin
I have been having an intermittent blower in the cabin and decided to bring the car into the dealer to have the car looked at. I just bought the car a few weeks ago and wanted to make sure it wasn't something serious. The dealer told me that there was a short in the blower motor and that it would cost $500.00 to fix. After doing some research this appears to be a VERY common problem on the prius as well as issues with the car door lock system.
View 8 RepliesLeSabre :: 2004 Replaced Blower Motor - Heat Isn't Working
A few weeks ago my battery died and I had to jump start my car. After the jump start, my heat wasn't working - no air will blow out on heat or A/C. I checked the fuses - all good.
I pulled the blower motor out and tested it and it worked hooked up to a battery. At one point when the blower motor was still in the car I banged it with a hammer and it turned on momentarily then shut off again.
Since the blower motor seemed to work outside of the car, I assumed it was the resistor that was bad. Replaced , and still no heat.
Could the blower motor be bad and just have worked hooked to a battery intermittently?
What else could it be?
Prius (2004-09) :: Red Triangle Of Death With VSC Came On
My 2007 proud of 180k miles which hasn't had any issues up until now just randomly gave me this error, where the red triangle of death, vsc, and tire pressure ((!)) Sign came on. It drives fine and there is no check engine light.
View 16 RepliesPrius (Gen 2) :: 2005 - Changed Evaporator And Now Blower Motor Doesn't Work
So the evaporator in my dads Prius had been leaking for a while so we finally decided to bite the bullet and change it. Everything came apart fine. Changed the evap and expansion valve. Put it pretty much back together except for glove box and a pillar trim pieces. Push power button twice to make sure all the flaps and blower motor works as it should. Well the blower motor doesn't come on. I hear the relay click when you turn the fan on in the mid. No power at the fan though. I checked just to be sure. I've looked all over for loose wires/plugs but have yet to find anything. I started the car up and everything works fine except the blower motor. What it could be?
View 13 RepliesFord Super Duty (1999-2016) :: 2004 - Blower Motor Speed Won't Work?
Have a 2004 F-250 and blower motor speed 3 is not working..replaced resistor pack with Motorcraft part and everything works except position 3 ....
View 6 RepliesPrius (2004-09) :: 2008 With 27k Miles - Red Triangle Of Death
I am a new Prius owner. I just purchased a 2008 with 27k miles yesterday, and last night I got the "red triangle of death". My car is currently back at the dealership after a very expensive tow. I only got to drive it for about 4 hours.
Before the break down, I was extremely excited to finally have a Prius, and was really happy with my purchase. I'm still excited about having the car, but I'm also highly disappointed that it broke down the day I bought it! I sure hope this isn't a sign to come! I see that most people love their cars, and I've read that they consistently get high dependability ratings.
Prius (2004-09) :: Triangle Of Death Came On, No Codes Detected
2005 with 123,000 miles. I have owned for a few thousand miles. Car was dealer maintained at every recommended interval. Car runs perfect.
After car sat for a week or so, I drove it and the red triangle popped up along with PROBLEM statement and take to immediately to dealer symbol. Red Triangle and other warnings repeats every once in awhile - will go a day without, and then will come on and off within a couple miles. Car continues to run fine. There are no other check engine lights. I have checked all the fluids and they are fine.
The battery charges fine, and holds the charge overnight. I have a generic code reader and there are no codes. I have read other posts, and there are always problems that seem to come with the Triangle. Gas mileage is fine as well.