Ford Super Duty (1999-2016) :: A/C Blows Form Defrost Only - Vacuum Pump?

Its hot in St. Louis and my windshield sure is staying cold (ac blows from defrost vents only).

1999 Ford F350 7.3 diesel 4x4 (4x4 lever on the floor). About a month ago, the ac starts blowing out of the defrost vents only. I assumed it was a vacuum issue.

Lines looked good; very plyable still. Canister looked fine. The vacuum pump on the pass fender well smelled burnt, so I replaced it. Got the new pump in and it didn't work. Checked the fuse panel and found two blown fuses, replaced them and the pump worked.

Here's my issues: if AC max is used, the vacuum pump stops working and air blows through defrost only . If the dash switch is in the off position and then turned back on, air blows through defrost vents again and vacuum pump will not work.

Is there a solenoid or switch to this vacuum pump that I'm not seeing?

View 10 Replies

Ford Super Duty (1999-2016) :: 2005 F250 - A/C Blowing Out Of Defrost

The A/C on my 05 F250 6.0 recently would not blow out through the vents. So, I replaced the vacuum pump and the reservoir tank. Once I replaced them the A/C still starts through the defrost vents but, after a minute or so starts to blow through the vents. I also noticed that the vacuum pump never stops running. Is this normal or is there something else I need to look for?

View 5 Replies

Ford Super Duty (1999-2016) :: 2005 F250 Blowing AC Through Defrost Only All The Time

My 2005 F-250 6.0 liter Diesel FX4 Lariat is blowing AC through defrost only all the time. I have manual locking hubs and when I engage 4x4 it works perfectly through the ESOF switch. So I am assuming the vacuum pump and lines to the hubs are in good working order but there is possibly a cracked line or fuse blown? I've only had the truck for 2 days and it just happened after purchase. I'm a little unfamiliar with checking vacuum but have done reading and I believe I can do it. I am going to get a manual hand pump and pump to 20lbs and loss shouldn't exceed 1lb per minute. I just need to know which direction to look. Everyone else had their 4x4 not working and I seem to be the only one posting that has ESOF 4x4 capability when the defrost only issue is on.

View 11 Replies

Ford Super Duty (1999-2016) :: 2005 - Vacuum Pump Starts Running And Won't Turn Off After Start Up?

I have a 2005 F250 , 4.2 tdi diesel. I just bought the truck recently and still getting to know it.

I noticed recently that when I turn on the key, the vacuum pump starts running and does not go off. It seems to run continuously and will only shut off if I block the white outlet pipe with my finger. Is this normal or is the pump stuffed.

View 6 Replies

Ford Super Duty (1999-2016) :: A/C Blowing Out Defrost Only

I have followed the vacuum lines but don't see any holes or cracked lines. I dont have the ESOF hubs so that is ruled out. Also checked the connector on the vacuum pump to make sure it still had power. Everybody says that when I turn the key to acc I should hear the vacuum pump running. I don't or do I feel it moving. Am I on the right track? I don't want to replace if not bad. Do all vacuum pumps run on keyed power? I honestly don't remember hearing it run before but that doesn't mean anything with my memory.

View 8 Replies

Ford Super Duty (1999-2016) :: Air Blowing Through Defrost Not Vent?

My husband and I have 3 Excursions, V10, 6.0, 7.3 and I have a 6.0 250 crewcab. 3 of the 4 now blow air or heat from just the defroster unless your going at a slow speed.

View 2 Replies

Ford Super Duty (1999-2016) :: F250 - AC Blowing Through Defrost

1999 F250 7.3 4x4 switch on dash with manual hubs. No visual vacuum hoses cracked.

Not sure what this component is but when I wiggle the wire at the orange cap a small motor kicks on.

View 3 Replies

Ford Super Duty (1999-2016) :: 2000 - A/C Blowing Through Defrost Vent?

I have a 2000 f250 4x4 7.3 diesel. I had problems with my a/c and controls for sometime now. my a/c was blowing threw the defrost vent. I was told my blend door was bad. I bought a new blend door installed it,still doing the same thing. I was told to check my vacuum lines. I check them, they were bad. I replace my vacuum lines and my vac pump as well. that fixed my problem blowing threw the defrost vent. I can control my air flow from floor,dash vents and defrost vent. the problem I have, I not able to control my temperature when I turn my center from red to blue. It blows hot air and the air that is coming out of the vents isn't very strong at all.

View 1 Replies

Ford Super Duty (1999-2016) :: No Air Blowing Out Of Vents Or Defrost For AC Or Heat

I have a 2008 F350 and there is nothing blowing out of the vents or defrost for AC or heat. It doesn't matter what fan speed is set. Would this indicate a blower motor? Where exactly is it located and how to change?

View 8 Replies

Ford Excursion :: Vacuum Leak - AC Is Blowing Through Defrost And Pump Is Running Nonstop

Ok, I know I have a vaccum leak. I have manual hubs now and those lines are capped. The AC is blowing through the deforst and the pump is running non stop. I have replaced the vac pump a couple of years ago and it worked fine then. any other places to look?

View 1 Replies

Ford Super Duty (1999-2016) :: Vacuum Pump Doesn't Shut Off In 4x4?

So my auto locking hubs have not been working for a couple years and I have just been locking them manually as needed. But now I have a boat and I like putting the truck in 4x4 at the landings just for added safety. It's difficult to manually put the truck in and out of 4x4 for just a few minutes when I know I have auto hubs. Plus I recently got aftermarket rims and they cover the manual locks, which can be accessed with a screw driver, but again, tough.

So today I bought the vacuum solenoid valve, whatever its called, and installed it, and they work! But the vacuum pump will not shut off while the 4x4 is engaged. The auto hubs work, my a/c controls work, everything works fine, the only symptom is the pump not shutting off. My a/c stays right where I put it, it doesn't go into defrost or anything, not even for a second, like it used to when my solenoid first started failing. Is the pump running normal? Or is there a leak on the other side of that solenoid? Should I even worry about it if everything else is working?

View 1 Replies

Ford Super Duty (1999-2016) :: AC Quits Blowing Out Of Forward Vents And Goes Into Defrost When Activate 4WD

02 F250 with 7.3. When I activate the 4WD, my light comes on, the A/C quits blowing out of the forward vents and goes into defrost and no 4WD. If I sit and wait a bit, the air again blows out the front vents and the 4WD engages. I figure I have a vacuum leak somewhere in the 4WD system. Is there a common place for this to happen or do I need to trace the whole system down? Also my manual hubs has never been turned and of course they won't. I know better than use a wrench so is there a easy way to free them up or just go ahead and disassemble and clean?

View 3 Replies

Ford Super Duty (1999-2016) :: 2004 F350 - Vacuum Pump Not Running

I have a 2004 F-350 diesel. My vent selector is always on defrost so I suspected a broken hose but traced all out and all seem to be fine. I disconnected the line coming from the pump to the tank and no vacuum. The pump doesn't seem to be running but it's hard to tell with the engine noise and vibration. What tells the pump to run and how can I bench check it?

View 8 Replies

Ford Super Duty (1999-2016) :: 2008 F350 6.4L - Vacuum Pump Continuously Running

I have a 2008 F350 FX4 with the 6.4l diesel, a couple weeks ago I was reprogramming the ecm and noticed the vacuum pump was running and wouldn't stop, so after a bunch of reading and testing i changed the solenoid vacuum valve. I tested all the vacuum lines and found no leaks.

View 3 Replies

Ford Super Duty (1999-2016) :: 2005 F350 - Vent Stuck On Defrost

I have a problem with my vent selector on my truck. It's a 2005 f350 lariat. The vent is stuck on defrost, some times after a few mins I can get it to switch to floor but not always. I have replaced the pump, checked tank for cracks, disabled and plugged the auto hubs. The pump will shut off so I assume it's not a leak. I believe it's in the switching unit, can these be repaired? I found a lot of dust and dirt in the vac tank that had been sucked through a bad hub. I think it may need to be disassembled and cleaned. I have seen videos showing how to replace the orings in the older units. Are the newer style remote ones the same?

View 5 Replies

Ford Super Duty (1999-2016) :: 2005 F250 - A/C Switches To Defrost When 4X4 Is Engaged

My 2005 F250 just had the cab off in December for head studs and gaskets. Its a Crew Cab short bed FX4 so it has ESOF. When I engage 4x4 the blower will switch from blowing air out of the vents to blowing air out of the windshield defrost. Is a vacuum line plugged in wrong somewhere, or is one cracked? Trying to figure this out, its rather annoying

View 2 Replies

Ford Super Duty (1999-2016) :: 2005 F350 4x4 - Vacuum Hubs Won't Disengage

I have a 2005 f350 with the power stroke I went through the hole vacuum system all new hubs, seals, vacuum actuator and fixed it all now I'm having the reverse problems everyone has my hubs are locked all the time as soon as I plug in the vacuum actuator the transfer case is still in 2wd and will switch 4x4 and work and disengage but the hubs are always in unless I unplug the actuator ...

View 6 Replies

Ford Super Duty (1999-2016) :: 2005 F350 - Vacuum Leak - Manual Locking Hub?

So I have an 05 f350 5.4 with the shift on the fly and the auto/manual locking hubs.. I already know I have a leak with the vacuum and I just use the hubs manually, then shift on the fly to activate the transfer case.

I went to use the 4wd the other night in a snow storm and I have no 4wd, light on the dash comes on and i can hear the transfer case clicking in when i hit the switch between 2wd and 4wd.

So I got under the truck while it was on the ground and manually locked the passenger side, Then tried spinning the axle and it wont spin freely, so obviously its locked.

Tried the same thing on the driver side and the axle spins freely while the hub is locked, So obviously the locking part of the hub is no good... So i guess my question is, even with just 1 wheel locking in the front, shouldn't I pretty much get 3wd? or am i missing something...will it not engage at all because both sides arent locked?

View 3 Replies

Ford Super Duty (1999-2016) :: 2005 F250 6.0 - Climate Control In Defrost Mode All The Time?

My 2005 Ford F250 6.0 diesel CLIMATE CONTROL DEFAULTS TO DEFROST mode all the time now. For some reason I'll turn on the AC and it is either already in defrost or changes to it no matter what I do. Is the head unit in the dash the problem or is it a vacuum leak or an electrical issue?

View 2 Replies