Camry 2012+ :: Toyota AC And Heater Stop Working / Only Blow Luke Warm Air

It blows luke warm air, no hot or no AC just luke warm... what could it be?

View 1 Replies

Ford 6.7L Power Stroke Diesel :: 2013 F250 Won't Cool After Towing

2013 6.7L F-250

The owner's manual recommends idling for a period of time after towing to allow the turbo to cool somewhat. After towing a 10K lb travel trailer in the mountains, what temperature should i shoot for as sufficiently cooled? When towing the oil to averages about 210-215-F. Normal operating temp is about 190F.

View 14 Replies

Ford 6.0L Power Stroke Diesel :: 2005 F250 Running Really Cool / Thermostat Replacement?

I recently noticed my 2005 F250 6.0 was running really cool, like barely making it out of the 170's. I guess it is time to replace my thermostat which I just replaced about two years ago. The question is should I replace it with another stock 192 degree thermostat or go for a 200 degree Mishimoto? I found where some where going to that one and it is supposed to make everything run better and the thermostat lasts longer. Any pros or cons to installing a hotter one?

View 7 Replies

Ford 6.0L Power Stroke Diesel :: No Heat Blow Cold Air Only?

today me and the wife where riding around doing some things before the snow storm. we went to the store and the heat was great but when we came out cranked the truck and all of a sudden no heat at all would just blow cold air. im not trying to go to a dealer and get charged an arm and a leg so where do i start.

View 14 Replies

Ford 6.0L Power Stroke Diesel :: Blue Smoke When Warm / Smells Like Oil Not Diesel

Started today. 2004 with 235k miles. Owned for last 10k miles. Engine was recently studded, has egr delete and ccv bypass. Runs and starts fine. New Ford oil cooler too. Checked for codes. None for misfires, perdel are reading 0.

If it sits, on start up clear exhaust, as it warms, more blue smoke. Smells like oil not diesel.

Researched before asking and found leaking turbo seals can cause this. So we pulled the intercooler tube in front of the engine going to the intake expecting to find oil residue. Nice and dry. Was this the correct one to look at?

When we got the truck we had the dealer do a relative compression test and was within limits, it did need 1 injector that we replaced. What would be the next logical place to look?

Couple more points:

- Just changed oil last week, checked today, it was slightly over full.
- Coolant is fresh and has not changed level since we got it.
- Pulled fuel filter to see if any oil, but it was nice and clean.

View 11 Replies

Ford 6.7L Power Stroke Diesel :: Takes Long Time To Blow Heat?

I'm thinking this is probably just the way they are, but I don't understand why........... I have a '12 F250 supercab 6.7 FX4.... truck is an XL, no supplemental heat or anything. If it sits outside over night, and I go out in the morning after say a 35-40 degree night, start it up and let it run 10-15 min then drive 5 miles down the road to town, both temp gauges are still pegged on the cold side, and there's virtually no heat blowing on the defrost. Even if it sits in the heated garage over night, same temp, same drive to town in the morning, same lack of any heat.

My old 2010 V10 that I traded for the 6.7, and my current 09 5.4 are the exact opposite of this. I can start the 5.4 cold, leave within a minute or two, and be making some heat within a few minutes. By the time I get to town, everything is well in the normal range, and I'm turning the heater down cuz it's too hot. Even once the 6.7 is fully warmed up the heater doesn't seem to make near the heat that the gas trucks do. I love the 6.7, I just find this a bit odd. Am I missing something, or is this just the way they all are?

View 14 Replies

Ford 6.0L Power Stroke Diesel :: 2003 F250 - All Injectors Blow Out At The Same Time

2003 F250 6.0. We had our truck completely checked over by a diesel shop, and we spent $ in repairs on our 6.0 in June having a new high pressure oil injection pump put in, 1 new injector, new oil cooler, new EGR cooler, FCIM and a few other odds and ends. We had this done before leaving Michigan to spend 6 months on the road for my husband's job while pulling our 5th wheel. We were on the road for 6 hours, got to the middle of Pennsylvania, and every injector blows out of the engine all at once. One head is cracked, all injectors are burned, brand new oil pressure pump is destroyed, oil is pouring out of the turbo. The mechanic we were towed to says we got bad fuel that caused catastrophic failure and he proceeds to rebuild our engine. 2 injectors were so badly destroyed that they could not be rebuilt. We had the fuel tested by a lab and the lab says the fuel is fine. What would cause such a catastrophic failure like this?

View 14 Replies

Ford 6.0L Power Stroke Diesel :: AC Blow Cold For 10 Minutes Until Everything Is Up To Normal Operating Temp

When I fire her up, the AC will blow cold for 10ish minutes until everything is up to normal operating temperature. Then it tends to blow warm, and that last for about 20 minutes, before finally settling back down and being cold AC again. I initially thought it was an issue with my compressor disengaging, but it doesn't seem to be...

View 3 Replies

Ford 6.0L Power Stroke Diesel :: Block Heater Plugged In When Starting - Blow A Fuse?

Ok, is it possible to blow a fuze if the block heater is still plugged in when starting? Almost did this the other day and wondered if its possible to cause a short or something.

View 6 Replies

Ford 6.0L Power Stroke Diesel :: 2006 F250 - Horn To Blow Steady Only When The Ignition Is On?

My 06 F250 horn would not stop blowing after I beeped to pass a guy. Since I have a toggle switch for my factory/air horn, I flipped the switch to center to cut the horn off. While the truck is running if I engage either horn system it blows. But with the truck off and key out, I can engage either system and it works normally, the horn only blows if you depress the wheel pad. I can hear the relay working correctly, clicking and the horn blowing, but only with the ignition off.

What can cause the horn to blow steady only when the ignition is on? It seems to me the air bag switch is working if it activates correctly when ignition off? I've searched until I am blue, but don't find anything positive and I don't want to throw an airbag at it to find out 800 later the horn still blows. Also, is there a replaceable relay for the horn?

View 1 Replies

Ford Super Duty (1999-2016) :: Luke Warm Air Blowing When In Max Heat

My manual heat/cold adjustment dial is working fine and transitions from heat to cold readily. However when in max heat, it is blowing luke warm. The higher the RPMs going down the road the warmer it blows (still not near as hot as normal), then idling at stop lights or in park it goes back to warm only.

My engine temperature is running normal at all RPM levels while driving and idling. Partially clogged heater core maybe, where higher RPMs force more water through it? I assume its not the water pump or thermostat since my operating temperature is staying normal...

View 13 Replies

Ford - Explorer :: 2002 - AC System Low / Luke Warm Air Out Of Driver Side Vents

Well I was recharging my a/c yesterday because the system was low so I used one of them 24oz cans and now I am getting cold air out of my passenger side and luke warm air out of my driver side vents. Also if I switch to the different vents I don't get anything out of the floor only. I get air out when I select it, but it's coming out of the defrost. Other than that everything else works just fine, just no floor. I've read issues with the blend doors but my vehicle doesn't have the dual climate controls so I'm at a loss...

View 4 Replies

Ford 6.0L Power Stroke Diesel :: Injector Spool Valves Blow Off Bodies - Broken Bolts

While diagnosing a low power and misfire condition on my 04.5, I was measuring coil resistance at the injector connectors. Found 1,3,7 had open circuits for one of the solenoids. 3 bad injector coils and no codes, no contribution codes... Why?

Anyway, pulled it apart to find the spool valves of 1 and 3 came out with the oil log the small bolts that hold them to the bodies had broken off. #7 only 1 bolt had broken off and the other was there but loose.

I got this truck with no history, and Had a variety of issues, like a bad fuse box that caused a no start, massive amounts of water in the fuel, and it had sat for 6 months untouched before I got it. I took care of the previous problems search for my previous posts if interested.

So what caused the spool valve to get blown off the bodies? I'm not sure if these have been rebuilt or ever removed, truck has 135 k. Could it be the water in the fuel that seized the intensifier piston?

View 14 Replies

Ford 6.7L Power Stroke Diesel :: AC Blowing Nothing But Warm Air

Well it's that time of year to start using my air conditioning. Went to use it today and it is blowing nothing but warm air. Worked perfectly last time I used it last year. I thought about buying that 134a ac recharge kit from auto zone.

View 14 Replies

Ford 6.0L Power Stroke Diesel :: Getting Little Warm Than Usual?

According to the scan gauge... I used to run about 195-200* all the time no matter what.

Now days i find myself up into the 220s and with my boat on ill see 235 climbing a hill.

Good deltas between the water/oil temps.

I wanna get back to my 200's.

I pressure washed out (on low) the front radiator and all the coolers, I didn't get much out and they didn't look dirty.

I am thinking water pump or plugged radiator?

View 14 Replies

Ford 6.0L Power Stroke Diesel :: No Power - Studders And White Smoky Exhaust When Warm

Say I just purchased an 06 f250 crew cab with the 6.0.

I had her trailered home due to dead batteries. I got her started up and drove about 5 miles until she got up to operating temp.

When I came to a stop and tried to accelerate, she immediately bogged down and started studdering with white smoke coming from the exhaust.

I shut her down and started her up again. She started and idled fine, but as soon as I pressed on the accelerator, she bogged and studdered again. I shut it down again and started it back up. Normal idle, and I shifted her into gear and was able to mozy on idling forward without having her bog, but as soon as I touch the accelerator, she bogs and studders.

I towed it home and the next day (today) she started just fine and I shifted her into drive and moved it forward about 10 feet. Did not touch the accelerator so she didn't big or studder.

1. I am guessing the white smoke was coolant burning through a failed EGR circuit. Do you seasoned members agree?

2. It the a check engine code when studdering. I have yet to check codes so I am still in diagnosis mode.

3. I plan to block off the EGR pipe and throw in a new oil cooler. Anything else immediate I should be considering??

View 14 Replies

Ford Super Duty (1999-2016) :: Luke Warm Air When HVAC Controls Turned To Hot

When my hvac controls are turned to hot, I'm getting only luke warm air. When moved over to cold it feels like the a/c is on...granted it is 21 degrees here. What I've done so far:

1. Flushed the coolant system at the local COOP TBA

2. Flushed heater core-Both heater hoses are hot to the touch as well as the heater core itself. The hoses are within 10 degrees of each other tested by an infrared temp gauge.

3. Verified the blend door actuator is moving. I can see it spin while attached to the box as well as I pulled it out and plugged it in it will move from hot to cold.

4. Smacked the #$%! out of the blend door box.

The fan still functions as it should from low to high. The truck also gets up to operating temp as usual.

Is it possible the actuator is still faulty even though it moves and not going all the way to the heat side? I considered picking up a replacement but I hate to start throwing parts at it.

Did the blend door give up? The snow is here and I need the heat for those 4am waterfowl hunting trips.

View 12 Replies

Ford 6.0L Power Stroke Diesel :: Starts Then Won't Start When Warm Outside

Left on hunting trip last Thurs. Blew tire on trailer 6 miles from home. Shut off truck. Went to restart, cranks only. No codes. Towed home.

Thought it might be a fuel filter problem. Had just changed oil/filter and fuel filters prior to trip. Checked filters, upper bowl was low. Turned key to on and bowl filled up. Noticed filter wasn't snapped in lid. Also checked lower filter.

Drove it to work this am. Turned off truck and tried to restart to check. NO START-Cranks fine!!!

View 14 Replies

Ford 6.0L Power Stroke Diesel :: Getting Warm And Puking Coolant

my 2006 6.0 will roll over 300,000 miles this week but today I was pulling a 24' pontoon boat that should only weigh a few thousand pounds from hot springs Ar where there are some small rolling hills and the outside temp was 70 degrees. I was driving between 55-60 most of the drive. On a few of the longer hills my eot got up to 220 with the eot trying to catch up.

On the down side it would fall to 185-190 and the eot would also follow. On about a 5 mile straight stretch the ect was 208 and eot 202. When I got home I opened the hood and I do have coolant puke around the degas bottle. After opening the cap there seemed to be a steam/smoke coming out of the degas bottle. There was still some coolant in the bottom but not a whole lot.

On my drive to work every day my delta is between 6-8 degrees with the ect between 188-194 depending on ambient temp. So does this sound like my head gaskets finally let go? Will them blowing raise the eot/ect when towing?

View 14 Replies