Celica :: 94 GT ST204 - Cranks / No Start And Not Even Fire Up At All - Code 12

I have a stock 1994 Celica GT with the 5sfe M/T .... I do have a headgasket leaking, and I am having another motor rebuilt and put in next month. I just need to nurse this one along for now. Right now it cranks but will not start. does not even fire up at all.

Code 12 - so I got another dizzy from the salvage yard, the pickup coils ohm out like they should as does the ignition coil. and I bought a brand new condenser for it as the old one tested bad. and when I first got the dizzy i put it in and it fired right up and ran for a couple days, then began doing it again. I went back to the salvage yard and grabbed another one that tested good, and when I put it in it fired up the first time but then shut off and has not started since.

But is it possible for the distributor to still be the problem even though the coils test ok? the shaft doesn't have any play in it, and the air gaps are within spec. I can barely get a .2mm between them. I also grabbed a couple of igniters while I was there. When I get it to run it may die when its cold and give me a code 14.

So from there I'm down to testing the distributor circuit, and the starter signal circuit, and the ECU. What is the best way to go about testing this to be Certain of what I need to go buy instead of just replacing stuff.

View 3 Replies

Caprice :: 1994 Doesn't Start At All Just Cranks

I got a caprice 94 l99 it was driving perfect. i was on my way home then it started to put put then the engine cut. gave it like 3 mins it started drove 1 block started to put then the engine cut. now doesnt start at all just cranks the gas gauge says it has 1/4 tank of gas.

View 5 Replies

Saab - 900 :: 1994 - Won't Start - Cranks But Don't Fires Up

94 Saab will not start in the mornings , it cranks but wont fire , runs fine later in day with no problems at all . Than next morning a repeat performance of not starting.

View 10 Replies

Geo - Tracker :: 1994 / 1.6L 16V Engine Won't Start, But Cranks

1994 Geo Tracker 1.6L 16V engine won't start, but cranks. I have spark, compression is good, fuel (good fuel), new spark plugs, the crankshaft and camshaft are timed, the distributor is timed, there are no error codes but the ECU is fine.

I've put in new spark plugs and wires, new fuel injectors, new timing belt, new air filter. All sensors are hooked up and working. It cranks, but doesn't start. It keeps burning fuel, I can hear it and feel it in the engine, but it won't start and run.

One thing which I've noticed is weird is the crankshaft is very difficult to turn when it hits certain points. I try to turn it and it will go about a third or a turn pretty easily, but then it gets stuck and I have to turn the key to get it past that point. Then I try to turn it by hand again and it has the same problem in a different spot. It hasn't started in a month at this point, I'm planning on taking the distributor out and realigning it tomorrow, but I'm running out of things to test.

View 19 Replies

Volvo - 850 :: 1994 Turbo Car Cranks But Does Not Start

My 1994 850 turbo will crank but will not start. it started when the car was having trouble accelerating past 40 mph and felt like it was kicking back then it died on the freeway and now will not start. i ran the error codes and got these back, from A2 452, 455, 543, 544, 545, 552, 555 and from A7 122. I'm not sure what to do?

View 4 Replies

Celica :: 1991 GT Cranks But No Start - Blinking Engine Light / Code 12

My cousins car died. cranks but NO start. It was not very well taken care of, but it is her daily driver. Threw a code 12, which is SOMETHING with the ignition.

Have replaced the...

distributer/cap/rotor
spark plugs
wires
ignition coil
valve cover gasket [unrelated HUGE oil leak]
100a ALT fuse

Timing is correct as far as i can tell, 12 volts at both wires for the ignition coil

Battery is good, alt is good...

View 1 Replies

Ford Ranger / B-Series :: 1994 - Engine Cranks But Won't Start

My kid is using my 94 Ranger with 215,000 miles. It quit while he was on his way to work. Engine cranks but won't start.

Fuel pressure at rail was 12 psi (Key on eng. off). I replaced fuel pump. Pressure at rail up to 20 psi. Still cranks, no start.

I replaced fuel filter. Pressure at rail up to 30 psi. Still cranks, no start.

Replaced distributor cap/rotor and plugs. I have spark at plugs.

Chiltons from 1994 doesn't list a rail fuel pressure. I see new fuel pressure regulators are set at 41 psi. I pulled mine and hooked air to it. It (FPR) cracks at 37 psi. I have lots of flow returning to tank, so I assume the fuel system is working correctly. I've never replaced the timing chain/sprockets. Distributor rotor spins during engine cranking. When I rotate the crank pulley to 0 Top Dead Center the rotor is pointing to #1 on the distributor, so I don't think the timing chain has skipped a tooth on the sprocket??????

View 4 Replies

Starting - Chevrolet - Capriceclassic :: 1994 - Engine Cranks Very Slowly Almost Does Not Start

1994 Caprice Classic (350 cid LT1)... Engine cranks very slowly, almost doesn't start, sometimes starter disengages/re-engages. 1year ago mechanic checked batty, alternator and starter, all ok. I had starter replaced as it seemed the most likely cause. Eventually got better but now is worse again. Also notice a lot of movement on the dash voltmeter needle, sometimes high, sometimes low, turn signal moves the needle. Ive spent hundreds of dollars on troubleshooting and the new starter. What could be causing this?

View 4 Replies

Celica :: 1992 Not Starting / Only Cranks When Warmed Up

I have a 1992 Celica 2.2. I've been having trouble with it starting after it has warmed up. I will go to start it and it will only crank but I can let it cool down normally like an hour and it will start up fine. I have replaced the ignition coil, fuel filter, spark plugs. And have checked the fuses and the distributor and they are fine. I wonder if its the actual fuel pump but I am no sure.

View 3 Replies

Celica :: 1994 GT Does Not Want To Run / RPM Gauge Jumps Up Down

94 celica GT 2.2 federal automatic, doesn't want to run, coughing, stalling, rpm gauge jumps eratically up down.

Computer says one code only, #12. Regarding Haynes manual it's distributor circuit or Igniter. When engine stops rotating (ignition still on), many times there is noise from distributor cap, like zzzzz....

System keeps shooting spark between distributor cap and rotor and there will be spark on that same spark plug !!!!!!

What's wrong? Distributor or Ignitor ??

View 2 Replies

Celica :: 1994 GT - No Heat At Idle

My son has a 1994 Celica GT with the 2.2 5S-FE engine. Recently told me his heat didn't work very well, he had mentioned it last year but due to extreme cold we've been having I decided I would look at it for him. So anyway, I started by pulling the thermostat thinking it was probably stuck open or possibly someone had removed it completely, well there was one in there and it was closed so I tested it in boiling water, worked fine, replaced it anyway.

So then I checked behind and under the dash, thinking maybe something was opening or closing completely, but they are connected and operating, when I move the controls inside I can hear the doors moving and closing and all the linkages under the dash are connected and operating. Still no heat, so I figured the heater core was clogged since the return hose didn't seem to be getting hot, or the heater control valve was bad, pulled the heater core hoses, checked the heater control valve, control valve worked fine and was not plugged. Flushed the heater core, nice clean antifreeze, I then checked it with air, manual said put 6 psi on the input and make sure it was coming out of the return, which it was.

Reconnected everything, bled the air, still nothing, took the hoses off and connected the return hose to the heater control valve, bypassing the heater core, both hoses got hot. Sure seemed like a clogged heater core, did the air test again with 2 psi, still made its way out the return side. Reconnected everything again, still same issue, return hose never got hot. So while it was running hot with thermostat open, I removed the return hose, nothing coming out of the core, then I revved the engine and it started coming out, reconnected it and ran car at 3000 RPM, finally a little heat out of the vent, about 115 degrees by thermometer placed in vent, as soon as I let it idle the temp fell back to 80 within a minute or so.

Now I figured the water pump impeller was worn/corroded or was slipping on the shaft, so I pulled the whole thing apart. ( I should mention that the entire cooling system is very clean I don't see any corrosion anywhere) Any of you that have done this knows what a pain in the butt the whole job is, anyway, when I got it apart I was surprised to see that the impeller looked like new and was definitely NOT slipping on the shaft... what the heck???

When I took the pump off the housing I noticed the housing had a lot of wear, it look as if the previous owner let the water pump fail to the point that the bearing wore enough that the impeller ground down the raised boss inside the housing, I though AH-HA, this has got to be the problem, water is not actually pumping/circulating inside the pump as efficiently as it should, hence the reason I only get coolant into the heater core at high RPM. So i replaced the housing, the water pump, and while I was in there I did all the oil seals, and the timing belt. Well I got it all back together, fired it up added coolant, let the engine come up to temp, bled air, still NO HEAT!

View 8 Replies

Celica :: 1994 - Idle With AC On Goes From 750 To 500 And Cycles Like That

I have a 94 gt with the 5sfe and at idle with the a/c on and up to operating temp the idle goes from 750 to 500 and cycles like that. It sounds like it is when the a/c compressor is cycling on and off but the compressor never disconnects the clutch unless I turn the a/c off. also when it drops in rpm the engine shakes bad. I have checked all the motor mounts and all are good and the rear one has a solid mount insert.

View 1 Replies

Celica :: Car Started Idling And Stalling - Now Cranks But No Spark

Car started idling funny and stalling. Finally wouldn't start. Changed crusty spark plugs, started up once, then stalled and wont start again. Checked for spark, no spark. Changed crust dist cap and rotor and ignition coil and still no spark. Checked ignitor activity and appears to be working.

What else is there? There's a little doofer next to the coil that looks like it has two wires come out of it, looks magnetic (has metal shavings on it, probably from old rotor)... Could the ignition switch be the problem? It cranks, but no spark.

View 9 Replies

Celica :: 1994 GT 2.2 With 5 Speed - Noisy Transmission?

I have a 1994 celica GT, 2.2 with a 5 speed. I thought I either had bad tire noise, or maybe a wheel bearing noise, I put the car up on jack stands, started the car and put it in gear, and the noise I have is a loud growling sound, which gets worse the faster the wheel spins. I took a 2x4 and stopped the passenger side tire (drive wheel) so the driver's side would spin, the noise went away. From what I can tell, or am guessing, the noise is coming from the trans. Could this be a bearing in the trans case? Of course I can't find an exploded view of the trans!

View 3 Replies

Celica :: 1994 ST 1.8L Engine Cuts Off While Driving

I have a 1994 Celica 1.8L ST which cut off on me while driving. I have been trying to troubleshoot the problem. Here's what I've done so far:

Originally after the engine would cut off I could get it to start again, but there came a point when it wouldn't start. I ended up replacing the ignition coil, and immediately the car fired up again and was running. However, the check engine light was now on and the engine had far less power and was running very rough. Nevertheless, the car was still working and would no longer cut off. Thus, I took the car to Precision Auto Tune to get a diagnostic test done, and they told me the distributor was bad.

I then purchased a new distributor and replaced the old one. Immediately the check engine light disappeared so I took the car out for a test drive and it ran perfectly; yet, after ten minutes, the engine suddenly cut off while driving down the road. After coasting the car to a place to park, it refused to start again. I left it overnight, tried starting it the next day and it randomly started. It ran for 10 minutes again in park before cutting off again. Since then, i thought the new distributor was faulty and exchanged it for another, but the engine still cuts off after running and refuses to start again. However, when it refuses to start, if I install the old "faulty" distributor, the car starts without a problem, but the check engine light also appears.

View 3 Replies

Celica :: 1994 - 100 Amp Alternator Fuse Blown

Just picked up a 1994 1.8 celica hatch and it was told to me that the 100 amp alternator fuse blew and there was some issue. So far haven't found any but I also cant seem to find this 100 amp alt fuse that goes in the fuse box under the hood. I don't have old one.

View 1 Replies

Celica :: 1994 / Dual Or Single Subwoofer Enclosure Box?

I have a 1994 Celica ST Coupe and looking for good dual or single subwoofer enclosure box that would fit neatly in the trunk against the back of rear seat.

I currently have a 12" Alpine in a huge box in the back- but it simply isnt practical. If I ever needed to remove my spare tire, I would have to disconnect the speaker and remove the entire enclosure.

View 2 Replies

Celica :: 1994 GT - Idle Speed Adjustment Screw

My 94 gt doesn't have the idle speed adjustment screw like the manual says it should so how does one adjust the idle speed?

View 7 Replies

Celica :: 1994 GT 2.2L Engine Temp Goes Up At Highway Speed

1994 celica GT 2.2L

Just happened last night, i was driving on the highway when i noticed my temp needle was reading about a 1/4 of an inch higher than normal. That's never happened before. It's always been rock steady right in the middle. I was doing about 80 miles an hour. i slowed down to about 65 and the needle went back to the middle. I sped up to 70 and the needle went back up again. So i slowed down again and it went back down.

Tonight i was on the highway again, but due to the freezing rain and hail, i was doing between 40 and 60. Tonight the Gauge never moved from the middle. It was steady all the way until i got on the off ramp at the light, Then it went up and came back down by itself. I didn't hear the fans come on. I went to a local parking lot to do some tests. I parked the car (gauge was in the middle), and reved the engine to raise the temperature. It went up and then came down. Fans did not come on. Strange. I them went back to my house. parked the car, put the hood up and tried to make the fans some on. Here's where it gets interesting...

while in my drive way, the needle goes up, both fans come on high speed, needle drops. I then tried to do it again. Reved the engine for a second, i hear both fans come on high speed, but the needle is in the middle. It did the same thing again with the needle in middle again.

There are no external leaks. engine oil is full. Both fans work, but on high. There is no debris covering the radiator. I replaced the thermostat around april 2011,( it was not a genuine toyota part and didn't have jiggle valve. is that ok? it's been fine all this time.) Timing belt and water pump have not been replaced (so i've been told).

Tomorrow i will check the coolant in the radiator, ignition timing, and check the radiator cap. What are the odds of it being the cooling fan switch or a relay? i only ask because it hasn't come on low speed since this happened. Will warm car up in drive way and see tomorrow.