Avalon 2005-12 :: 2009 - Blower Motor Speed Does Not Blow Hard On High

My blower motor does not blow hard on high. 2009 AVALON.

View 3 Replies

Avalon 2005-12 :: 2007 Toyota AC Only Blow On The Lowest Temp

I have 2007 toyota avalon limited. Just had evaporator replaced and now AC only blows on the lowest temp. If you try to adjust temp it just switches to blowing hot. I think it might be the ac/heat actuator. I do have dual zone ac. I don't want to just start replacing parts.

View 5 Replies

Avalon 2005-12 :: 2007 - Fan Blower Will Only Run On High Speed Intermittently

Fan blower will only run on high speed intermittently.

View 1 Replies

Ford Super Duty (1999-2016) :: 2005 F350 - AC Will Not Cycle / Blower Only Blow On High

2005 F350 Lariat ..... I cant get my AC to work in my truck.

AC will not cycle on, Originally thought the system was low because I jumped the pressure switch and it cycled fine (But did not cool inside the vehicle). Checked the pressure and it was in the 40lb range on the low side. My blower will only blow on high but I assumed it was a defective fan speed control.. Possibly an issue with the climate control?

View 12 Replies

Avalon 2005-12 :: AC Goes Off At Times And Check Air Conditioner Display On Command Center

07 Avolon Limited? My A/C goes off at times and it sometimes say Check Air Conditioner on the "Command Center." I took it to Toyota and they replaced the A/C relay for $80.00 and it still does the same thing. The Air is cold coming out of the vents until this happens. Toyota says the next thing is to replace the A/C surpintine belt and next the compressor. The replacement game gets very expensive when it doesn't fix maters!

View 5 Replies

Avalon 2005-12 :: 2013 XLE Engine Buzzing Sound And Vibration Intruding Into The Cabin

I have totally insulated my 2013 Avalon XLE with the sound deadening materials. Now, I can hardly hear or feel any engine noise or vibration at any speed unless I really accelerate the engine hard. I have also insulated my wife's 2012 Camry LE but I have not been able to eliminate the typical 4 cylinder engine buzzing sound and vibration intruding into the cabin. I am wondering if the Avalon Hybrid does the same once the 4 cylinder engine kicks in even though it is better insulated than the Camry.

View 1 Replies

Avalon 2005-12 :: 2013 - Wind Noise In Rear Passenger Doors During Highway Driving

Having wind noise in the rear passenger doors when highway driving? I checked the rubber door seals and they appear to be ok. 2013 Avalon.

View 12 Replies

Avalon 2005-12 :: 2013 V6 - Check Blind Spot Monitoring System Appeared / BSM Stopped

I have a 2013 Avalon V6 Limited.

On 5 or 6 occasions, during the 8 weeks I have owned it, a yellow warning light has appeared, together with a message on the Multifunction Display stating: "Check Blind Spot Monitoring System." While this is displayed, the BSM does not work. Turning the ignition off and then on again resolved the problem immediately each time, with one exception, when I had to do it twice. Pushing the On-Off button for the BSM on the left side of the dash did not resolve the problem.

View 14 Replies

Ford - Fivehundred :: 2005 - AC Will Blow Cold When Running Fast And Then Blow Hot

I'm at the end of my rope! My 2005 Ford Five Hundred Limited has a constant problem with the A/C system and overheating. In the last year I've replaced the compress, expansion valve, dryer FOUR times. They have replaced the condenser, blower motor, and added Freon, and checked for leaks. It will blow cold when running fast and then blow hot. They have replaced belts pulleys, They have replaced the thermostat, fans, coolant reservoir, hoses. and it still overheats. I've taken it to 4 difference mechanics including two dealerships. No one can seem to fix this problem.

View 9 Replies

GMC - Safari :: 2000 - Max Blower Position Does Not Blow At All

Symptoms:1. The max blower position does not blow at all, but the other positions blow just a little (heat and a/c).2. The heater seems to take a bit to get going. Once it is hot, it seems to do okay.

Questions:1. What steps do I take in a logical order to fix this? Resistor, blower motor, thermostat, heater core?2. This is a loaner van from a family friend. Should I do anything to it? They want to sell it and I am interested in it, but I don't want to start fixing stuff if I am not going to own the thing - unless it is an easy repair under $100.

View 7 Replies

Ford A/C :: 2008 F250 - Blower Motor Quit / Just Won't Blow

Blower Motor quit, dual zone climate control system. AC will work with Recirculation mode off. Just won't blow.

Turned heater on still won't blow. Pulled and checked the following fuses: 37; 45, 37 & 15 which pulling these 3 reset the system; and pulled 24 in the battery junction box. Still not working.

Next plan is to pull Relay #1 from the battery junction box and apply 12v to see if it clicks - no click & then I'll replace it.

View 2 Replies

Ford F-150 (2004-2008) :: AC Does Not Blow Cold At Times / Compressor Not Coming On

I have a 2007 F150 with a 5.4. I am having an issue with my A/C and more.

Here are the symptoms:

1) A/C doesn't blow cold, at times.
2) Compressor not coming on, according to mechanic.
3) Engine sounds like a freight train, at times. Like on a super cold day and it has to work hard.
4) Very poor fuel mileage since this started.

I took it to a shop, and they said it was the engine cooling fan that would not come on. So I replaced it. Same issue. I then took it back and was told there is a wiring problem. After 3 days they couldn't find it. I needed my truck back and dropped it off again. Then they said it was the A/C compressor, maybe. They wanted to try it and then see what happened. I told them no way.

Temperature, according to the gauge is good. Noise comes and goes. Not dependent on anything. Weather, temperature, car heated up or dead cold. Just comes and goes.

View 3 Replies

Toyota - Sienna :: 2007 - Interior Blower Takes 20 Minutes To Blow Hot

The dash temp gauge reads in the middle between hot and cold within a few minutes of running. However, it takes about 20 minutes for hot air to come out the heater vents when the heater is set to maximum heat and the fan is on. What should I check and in what order?

View 19 Replies

Ford Aerostar :: 1997 XLT - Front Blower Motor Does Not Blow Occasionally

My 1997 XLT 4.0 AWD w/Rear A/C has been having a Blower Motor issue for many months. Occasionally the front blower does not blow. Banging on the Blower Motor, either from under the hood, or even from inside the van underneath the glove box, will start it up again. Once running, it continued running okay until at least the next shutdown. This has gone on throughout the summer. Sometimes a good bump in the road would start it.

Now that the winter is here, heat and defrost are more critical, so it has become a bigger problem. Furthermore, is is now almost constant, where it rarely works without a bang. So it is time to actually fix it now.

From other posts, I think it is either the Blower Motor itself, or the Control Module / Resistor. But since the control module is not located on the motor itself, where I bang, it is probably the motor. Question:

1 - What is the problem, and can I fix it with grease (elbow or actual) etc... or is replacement the proper option?

2 - Should I replace the wheel too, which is not available on RockAuto - but is on the junkyard options on eBay. Unfortunately those are often just as broken as mine. Generic Wheels are available in Auto Zone.

View 5 Replies

Toyota - Avalon :: 2000 - A/C Making Grinding Noise And Does Not Blow Very Cold Air

I have a 2000 Toyota Avalon. The A/C will only come on if the switch is turned to full blast, but even then it makes a really loud grinding noise and does not blow very cold air. Is this a compressor issue or blower motor? I am assuming the switch is bad since it only works on highest speed, but could it be something else causing this also?

View 3 Replies

Ford - Crown Victoria :: Blower Fan Does Not Turn Off - Came On High All Times

I have a 2003 Crown Victoria. Within the last year, I changed blower fan resistor (or Blower fan control module) and repaired the Electronic Climate Control Module (the thing inside the cabin that controls A/C, heat, defrost and fan speed). Today, while I was driving, the blower fan came on high and would not stop. The weather was mild, so I did not have the A/C or heat on at the time. I tried pressing various buttons to make it stop, but it was running at high and wouldn't stop. The only way to make it stop was to turn off the engine. When I turn the engine back on, the blower fan was on high again.

What could possibly be wrong with the car? I recently changed the blower fan resistor, so that is unlikely to be the culprit. Even if it is, why wouldn't it shut off? Other people with a bad blower fan resistor say that the speed control is stuck on high, but the fan can be turned on and off.

Could it be the electronic climate control module inside the cabin? After all, it is the unit that tells the blower fan to go on. Air could be directed to defrost, vent and floor without any problem.

What do you think is making the fan stay on at HIGH and does not turn off?

View 16 Replies

Ford Super Duty (1999-2016) :: Heater And AC / Blower Doesn't Seem To Blow Very Hard

My blower doesn't seem to blow very hard. I've been in other fords and the ac and heat blows great. Someone suggested that that I pull the fan motor and clean the blades.

View 4 Replies

Ford Super Duty (1999-2016) :: 2000 F250 - Blower Would Only Blow On High

My dad has a 2000 f250 4x4 with the 5.4. he said his blower would only blow on high. I told him it was his blower motor resistor. i thought it was under glove box. he took it apart and said no but there was a little box thing with wires he took off anyway and put back on. I then told him it was under hood below a/c lines. he replaced old one with a new one from auto zone and replaced the pigtail( plug too) fan works on high and a little bit on low very very little when u switch it to medium it stays the same. High works great. So we replaced the fan switch. (Radio was a bitch to remove) and it still does the same thing. I checked all fuses . when I check the plug at the resistor there is power to the center pin it stays on when u switch to low and medium but when u turn high on power goes out( on test meter) is there something I am missing? the blower blows on high even when u remove the plug from the resistor. Is that normal?.

View 4 Replies

Lexus - Engines - Blower-motors - 300 - Rx300 :: 2000 - Loud Noise At Times

I have a 2000 Lexus RX300, with over 200k miles. The motor blower is making this very (at times) loud noise. To take a closer look, I removed the glove compartment to take a better look at the unit itself. I took a closer look at the blower motor itself and it looks like the top piece of the cone is cracked a little. This is where the little clamp ring is located on the tip of the cone. The noise is definitely coming from this area. I was going to just replace it, but could there be anything wrong with maybe one of the servo motors as well (Airmax or Mode)? It seems that at times (out side of the main noise) the air is not being distributed properly.

View 4 Replies