Ford Super Duty (1999-2016) :: F250 - Exhaust Manifold Leak On Passenger Side
Should I attempt to replace the passenger side manifold with what I can get from Napa. I would rather pay 100 bucks for everything and do it myself. But, Im concerned about replacing the studs. From what I have read the studs seam to be the problems for most leaks on these vehicles. I have torque equip. and other tools to do the job. Just want others opinions about this project. How hard really is it? 1999 5.4L F250 SDuty....
View 14 RepliesFord Super Duty (1999-2016) :: 2006 F250 - Leak At The Driver Side Exhaust Manifold
I have a leak at the driver side exhaust manifold. Its a little tough getting at it to tell if its a lose bolt, crack or bad gasket. What would be the best way to get at this area? Should i remove the tire and wheel well or is their a better way. If i can get at it i may replace the manifold all together.
View 2 RepliesFord Super Duty (1999-2016) :: Exhaust Manifold Leak Repair
The exhaust leak is not too horrible, but, enough that I need to address it soon. Only on the driver's side; (today).
I'm planning on having a lot of PB blaster on hand, torch, broken stud removers, screw/stud extractors (easy outs), ...a hammer. Maybe a few cold Budweisers
Ford Super Duty (1999-2016) :: Exhaust Manifold Leak Causing CEL To Blink?
I've got a 2006 F250 5.4l. Recently Ive had an issue when I am driving, usually when the engine is at 3k+ RPMs, where the engine will lose power and the cel with blink. Usually it only takes a few seconds for the blinking to stop and the engine continues as normal. Now, I know that at least one of my exhaust manifolds are leaking.
Could it be that the engine is not receiving enough back pressure and that is causing it to lose power? I had a similar issue last year, basically the same symptoms, and it turned out that I had two cylinders misfiring. I replaced the coil packs and that fixed it. This time there are no codes referring to a cylinder misfire. There is a code for EVAP leak (I think), but I was told it was nothing to worry about.
Ford Super Duty (1999-2016) :: 2003 F350 V10 - Exhaust Manifold Leak?
2003 F350 short bed 6.8L V10---On start up a slight tap sound, almost like a cranky lifter, but it is an exhaust manifold leak. At the bolts, I am not sure. This has been this way for 5 years, no better no worse. After I run about 2 to 3 minutes it seals itself. Not a hint of noise. Due to heat, something is expanding to seal it (aluminum).
At my annual PA. State Safety Inspection the Tech says 'that has to be corrected if it worsens', but It does not fail inspection. This puzzles me.
How is the call made for correction. A flip of the coin, a guess and is it serious enough to fail inspection. Is this normal with the 6.8L or V10s. I know the cost involved for a fix is big league, but can it be justified. TRUCK RUNS GREAT !---
Ford Super Duty (1999-2016) :: Rough Idle - Exhaust Leak Between Manifold And Turbo
I have an exhaust leak between the manifold and turbo ( in the flex part of the pipe) on my 2008 6.4 f250 would this create rough idle when at operating temp?
View 2 RepliesFord Super Duty (1999-2016) :: 2003 F250 - Exhaust Manifold Gaskets?
About to do the exhaust manifold gaskets on my 03 f250.
View 3 RepliesFord Super Duty (1999-2016) :: 2003 F250 - Lost MPG After Exhaust Manifold Replacement
I have an 03 F250, 5.4, 4x4, with aprox. 130k miles. I recently had my exhaust manifolds replaced because 1 literally cracked in half. Ever since the replacement, I'm getting worse gas mileage! Im only getting aprox. 250 miles to a tank when before it was well over 325 (highway)...
View 1 RepliesFord Super Duty (1999-2016) :: 2008 - Cracked Exhaust Manifold
My '08 S.D. (5.4) has a cracked exhaust manifold, which I've heard is fairly common. Crappy Ford design. The local dealer has them in stock (imagine that, just like the 'non-bad' coil caps from some years ago, that they were instructed by Ford to keep at least 10 on stock at all times) for the passenger and driver's side. What are the part numbers?
View 10 RepliesFord Super Duty (1999-2016) :: 2005 F250 - Passenger Side Exhaust Manifold Is Leaking
I have a 2005 f250 5.4 no mods. its got 120k and needs a wake up. the passengers side exhaust manifold is leaking to the point of fixing and would like to get some input before the big purchase. my question is, headers or new manifold, and what brands is preferred for both I really don't prefer one or the other i just want the best fix really. Changing coil pack and getting more performance out of them and if so what brand. I would like a boost in lower end acceleration and throttle response, like a programmer or such. and if so what brand once again.
View 10 RepliesFord Super Duty (1999-2016) :: 2006 F250 - Exhaust Manifold Leaking On Driver Side
Whats the best way to get at the driver side exhaust manifold? I have a leak and its tough to get at. Should I remove the tire and inner wheel well?
View 1 RepliesFord Super Duty (1999-2016) :: P0420 Code - Leak At The Joint Where Exhaust Manifold Meets Pipe Beside The Engine
I have a 2011 F350 CC long box 4x4, with a 6.2, 93,000 km on it. I periodically get a P0420. I clear it and sometimes it comes back in 10 or 20 KM and sometimes it comes back in a couple hundred km. Been doing this for about 800 KM.
Yesterday I got an exaust leak at the joint where the exaust manifold meets the pipe beside the engine. Checked close, bolts appear intact, leak is on the outboard side blowing towards the frame. Looks like a gasket or donut seal failed.
I am wondering if the catalytic converter was plugged or restrictive, would this cause the P0420 and could back pressure from a restricted catalyitic converter cause the gasket to blow?
Ford Super Duty (1999-2016) :: 2008 F450 - Lost Both Turbos / Exhaust Manifold Bolts Broken
Our F-450 with 102000 miles lost both turbos also broken exhaust manifold bolts. This truck carries tools fuel tank and sometimes skid loader on trailer. Heard lots of bad things about 6.4 liter motor now first hand experience. Asked dealer if 6500.00 bill could be reduced since so close to 100000 mile warranty and was told nothing could be done. Can not afford to sell truck now also have two other Ford F-250s newest one 2012. Is there any other approach that could be taken to get some relief from this expense.
View 14 RepliesFord Super Duty (1999-2016) :: 2008 F450 - Driver Side Exhaust Manifold With A Cracked Abd Broken Bolt
I got a 08 ford f450 sd in the shop with a cracked abd broken bolt in the driver's side exhaust manifold, any tips tricks on getting it out,I have everything loose but I can't for the life of me get the egr cooler out of the way to access the top bolts to the manifold so I can replace the manifold, or a link to a service manual would be great.
View 3 RepliesFord Super Duty (1999-2016) :: 2003 F250 V10 - Heat Shield Rattle That Sounds Like Exhaust Leak During Loaded Acceleration
I recently purchased this truck and have towed a couple of times with it. It has 98,000 miles and I do not know if the automatic transmission fluid has been changed. Should I have it flushed or drop the pan and change it? I have a lift so doing the change is no problem, although it might be worth it to pay a transmission shop to do it.
Also, I hear what appears to be like a heat shield rattle or something that sounds kinda like an exhaust leak during loaded acceleration. What to look for to locate the noise? One last question, the air bag light is on sometimes then off sometimes. Any known air bag light issues? I love the truck, hate the gas mileage!
Ford Super Duty (1999-2016) :: 2008 F250 - Light Smoke And Heavy Exhaust Smell
I have a 2008 6.4L F-250 and occasionally when I come to a stop I can see a faint white smoke coming out from under the truck and the hood. The smoke has a heavy diesel exhaust smell. When I step on the pedal nothing comes from the exhaust and it does not happen all the time. What is going on?
View 2 RepliesFord Super Duty (1999-2016) :: F350 V10 - Exhaust Manifold Bolts Breaking
Bolts breaking on the exhaust manifold. If so why isn't ford doing a recall on this problem I have a F350 V10 90K miles and 3 on the top drivers side are missing not sure on the passenger side. Is this a problem with all the ford engines I have never had this problem with any other truck or car I have owned.
View 5 RepliesFord Super Duty (1999-2016) :: Broken Exhaust Manifold Bolts - Long Term Fix?
I've got the dreaded broken exhaust manifold studs on my 2004 F250 V10. I don't drive it much (just 50,000 miles in 10 years) and confess I've ignored the hissing for quite a while. Is there really a permanent fix for these broken studs? Or should I expect to be replacing broken studs every 2 or 3 years?
If there is a permanent fix what is it? Special studs? Special manifold? I want to keep this truck a long time and don't want to be replacing these studs every few years.
Ford Super Duty (1999-2016) :: 2008 F250 - Transmission Cooler Line Start To Leak
I have a 2008 Ford F250 V-10 Superduty and recently I had a transmission cooler line start to leak. I ordered replacement lines and the tool for the quick disconnect. The line that's leaking is from the radiator to the quick disconnect. I was able to replace the one line, however the second line (problem area) has been a nightmare. The line cracked right at the quick disconnect fitting.
The hard line is tight in the fitting and corroded. broke the tool trying to remove from disconnect. The line is flush with the quick disconnect. How to get that out of the fitting? or another method of fix? Its a hard 1/2 line going into connect crimped to rubber line going to transmission.